Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Spraul, M.
Right arrow Articles by Berger, M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Spraul, M.
Right arrow Articles by Berger, M.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 10, Issue 3 357-359, Copyright © 1987 by American Diabetes Association


ARTICLES

Less expensive, reliable blood glucose self-monitoring

M Spraul, GE Sonnenberg and M Berger

We examined the reliability of split test strips for blood glucose self-monitoring. One hundred visual readings were performed with each of the following test strips: original Haemoglukotest 20-800 (HGT 1/1; Boehringer-Mannheim, Mannheim, FRG) and Haemoglukotest 20-800 halved either by a splitting device (HGT 1/2 SP) or by a pair of scissors (HGT 1/2 SC). Within the plasma glucose range of 20-360 mg/dl, there was a close correlation between the results of all three test-strip readings and the values obtained by the reference method (Beckman glucose analyzer): HGT 1/1, r = .950; HGT 1/2 SP, r = .966; and HGT 1/2 SC, r = .966. Absolute deviations from the reference values were 17 +/- 2, 17 +/- 1, and 17 +/- 1 mg/dl (mean +/- SE). Analysis of variance did not reveal any significant differences between the values of each of the three procedures compared with the reference method (P = .98). These results indicate that visual reading of split test strips is as reliable as the reading of original test strips. A special splitting device is not necessary. Diabetic patients should be advised to use split test strips for blood glucose self-monitoring to reduce costs.