Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Mogensen, C. E.
Right arrow Articles by Willamowski, K. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mogensen, C. E.
Right arrow Articles by Willamowski, K. D.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 20, Issue 11 1642-1646, Copyright © 1997 by American Diabetes Association


ARTICLES

Multicenter evaluation of the Micral-Test II test strip, an immunologic rapid test for the detection of microalbuminuria

CE Mogensen, GC Viberti, E Peheim, D Kutter, C Hasslacher, W Hofmann, R Renner, M Bojestig, PL Poulsen, G Scott, J Thoma, J Kuefer, B Nilsson, B Gambke, P Mueller, J Steinbiss and KD Willamowski
Medical Department M, Kommunehospital, Aarhus, Denmark.

OBJECTIVE: To assess the performance of the Micral-Test II immunologic test strip for the detection of microalbuminuria, a multicenter evaluation in eight European study sites was performed. RESEARCH DESIGN AND METHODS: Using both the Micral-Test II test strip and the routine method for the determination of albumin concentration, we investigated 2,228 urine samples from diabetic patients. Additionally, interperson variability, color stability, and possible interfering factors (temperature, pH, leucocyturia, erythrocyturia, and drugs) were tested. RESULTS: For a cutoff concentration of 20 mg/l with respect to the routine methods, a sensitivity of 96.7% and a specificity of 71% were calculated for the Micral-Test II test strip. The negative predictive value was 0.95, and the positive predictive value was 0.78, with a prevalence of positive samples (laboratory method) of 52%. The interperson variability of color interpretation showed 93% concordant readings. The interference study showed an influence of oxytetracycline, leading to higher readings. There was no interference from pH. A sample temperature of < 10 degrees C led to lower readings. In the case of samples with massive leucocyturia and erythrocyturia that may delete the chromatographic process, waiting an additional 1-2 min is needed before reading. CONCLUSIONS: The results of the multicenter evaluation show that the Micral-Test II test strip permits an immediate and reliable semiquantitative determination of low albumin concentrations in urine samples with an almost user-independent color interpretation.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1997 by the American Diabetes Association.