Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Renner, R.
Right arrow Articles by Landgraf, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Renner, R.
Right arrow Articles by Landgraf, R.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 22, Issue 5 784-788, Copyright © 1999 by American Diabetes Association


ARTICLES

Use of insulin lispro in continuous subcutaneous insulin infusion treatment. Results of a multicenter trial. German Humalog-CSII Study Group

R Renner, A Pfutzner, M Trautmann, O Harzer, K Sauter and R Landgraf
3rd Medical Department, Hospital Munchen-Bogenhausen, Germany.

OBJECTIVE: Insulin lispro is an analog of human insulin with a faster onset and a shorter duration of action than regular human insulin. Efficacy and tolerability of insulin lispro in continuous subcutaneous insulin infusion (CSII) treatment were assessed in an open randomized crossover trial comparing insulin lispro and regular human insulin, both applied with insulin pumps. RESEARCH DESIGN AND METHODS: A total of 113 type 1 patients (60 male, 53 female, age [mean +/- SD] 37 +/- 12 years, duration of diabetes 19 +/- 9 years) participated in this open, randomized crossover study. Both insulins were applied for 4 months each with the appropriate intervals between the prandial insulin bolus and the meal (human insulin: 30 min; lispro: 0 min). Observation parameters were HbA1c, daily and postprandial blood glucose profiles, adverse events, rate of hypoglycemic and hyperglycemic events, number of catheter obstructions, and treatment satisfaction as assessed with an international validated questionnaire. RESULTS: The patients were well controlled with a mean HBA1c of 7.24 +/- 1.0% at baseline. HbA1c decreased in both treatment periods, but it was better during insulin lispro treatment (insulin lispro: 6.8 +/- 0.9%, regular human insulin: 6.9 +/- 1.0%, Friedman's rank-sum test: P < 0.02). In addition, the 1-h and 2-h postprandial rises in blood glucose were significantly lower (P < 0.001 for each meal) with insulin lispro, resulting in smoother daily glucose profiles as compared with regular human insulin. No significant differences were reported for the rate of hypoglycemia (mean +/- SD [median]: insulin lispro 12.4 +/- 13.9 [8], regular human insulin 11.0 +/- 11.2 [8]), for the rate of catheter obstructions (42 events in each treatment arm), and for the number and type of adverse events. No severe case of ketoacidosis was seen during insulin lispro treatment, whereas one case was reported during therapy with regular human insulin. Treatment satisfaction was better when patients were treated with insulin lispro. CONCLUSIONS: Insulin lispro is a suitable and very convenient pump insulin that may result in an improvement of long-term glucose control during CSII treatment. Its safety profile does not differ from that of regular human insulin.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1999 by the American Diabetes Association.