Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jensen, T.
Right arrow Articles by Stender, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jensen, T.
Right arrow Articles by Stender, S.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Diabetes Care 25:1914-1918, 2002
© 2002 by the American Diabetes Association, Inc.


Clinical Care/Education/Nutrition
Original Article

Comparison of a Homogeneous Assay With a Precipitation Method for the Measurement of HDL Cholesterol in Diabetic Patients

Tonny Jensen, MD1, Quan Truong1, Merete Frandsen1, Bo Dinesen, MD1 and Steen Stender, MD2

1 Steno Diabetes Center, Gentofte, Denmark
2 Department of Clinical Chemistry, KAS Gentofte, Hellerup, Denmark

OBJECTIVE—To compare direct-measured HDL cholesterol with HDL cholesterol measured by a precipitation method.

RESEARCH DESIGN AND METHODS—We compared a homogeneous assay for direct HDL cholesterol analysis with the phosphotungstic acid magnesium chloride precipitation method in 55 type 1 diabetic patients, 70 type 2 diabetic patients, and 82 nondiabetic normal control subjects with plasma triglyceride levels <4.6 mmol/l. The cholesterol content of HDL determined by the direct assay was overall 0.1 mmol/l higher in all three groups than HDL cholesterol measured after precipitation, but the two methods were closely correlated (r2 = 0.98, P < 0.001).

RESULTS—HbA1c, blood glucose, serum albumin, serum bilirubin, or triglyceride did not influence the differences of the two HDL cholesterol measurements. Because we have previously shown HDL cholesterol isolated by phosphotungstic acid precipitation to be lower than that by ultracentrifugation, the positive bias found in this study was expected. It seems that the direct HDL cholesterol assay reacts with apolipoprotein (apo) B-containing lipoproteins in the fraction with a density of >1.063; these apo B-containing lipoproteins are suggested to be coprecipitated with the phosphotungstic acid method. We also measured LDL cholesterol directly by a LDL cholesterol plus method and found no significant differences between this method and LDL cholesterol calculated from Friedewald’s formula.

CONCLUSIONS—Direct homogeneous assay for HDL cholesterol determination in diabetic patients seems not to exhibit a negative bias, in contrast to the precipitation method, when compared with the ultracentrifugation method. In addition, the direct assay saves time and is not influenced by type of diabetes or degree of metabolic control.

Abbreviations: apo, apolipoprotein


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 2002 by the American Diabetes Association.