Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Malchoff, C. D.
Right arrow Articles by Buchert, J. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Malchoff, C. D.
Right arrow Articles by Buchert, J. M.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Diabetes Care 25:2268-2275, 2002
© 2002 by the American Diabetes Association, Inc.


Emerging Treatment and Technology
Original Article

A Novel Noninvasive Blood Glucose Monitor

Carl D. Malchoff, MD, PHD1, Kamal Shoukri, MD1, Julian I. Landau, MS2 and Janusz M. Buchert, PHD2

1 University of Connecticut Health Center, School of Medicine, Division of Endocrinology and Metabolism, Farmington, Connecticut
2 Infratec, Inc., Wilton, Connecticut

OBJECTIVE—To evaluate the precision and accuracy of a new advanced prototype of a noninvasive blood glucose monitor across a wide range of serum glucose concentrations.

RESEARCH DESIGN AND METHODS—An advanced handheld noninvasive glucose monitor prototype was calibrated and tested using patients recruited by the General Research Center of the University of Connecticut Health Center. The monitor, developed by Infratec, uses principles of thermal emission spectroscopy. The noninvasive measurement of tympanic membrane glucose concentration was calibrated to the serum glucose concentration using 432 paired measurements from 20 subjects with insulin-requiring diabetes. This calibration was subsequently tested (results of power analyses) in a blind fashion with 126 paired measurements from six diabetic subjects who require insulin.

RESULTS—In vivo measurements demonstrated the reproducibility of the methodology of the noninvasive glucose monitor. Based on the calibration model, predicted glucose concentrations for six subjects were as follows (for 126 data points): SD = 32 mg/dl, mean absolute relative error (%MARE) = 11.6, with a correlation coefficient of r = 0.87. Noninvasive glucose results were also compared with laboratory reference measurements using an error-in-variables method. Clark error grid analysis showed that 100% of the measurements fell within zones A and B (90% in zone A and 10% in zone B). The SD for all noninvasive measured concentrations was 27 mg/dl, %MARE was 8.6, and the correlation coefficient was r = 0.94.

CONCLUSIONS—This first independent clinical study of an advanced noninvasive blood glucose prototype based on thermal emission in the mid-infrared spectral region has demonstrated glucose measurements with clinically acceptable accuracy but without the necessity of individual daily calibration.

Abbreviations: %MARE, mean absolute relative error • BG, blood glucose • IR, infrared • TES, thermal emission spectroscopy


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Journal of Pharmacy PracticeHome page
A. L. Briggs and S. Cornell
Self-monitoring Blood Glucose (SMBG): Now and the Future
Journal of Pharmacy Practice, February 1, 2004; 17(1): 29 - 38.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 2002 by the American Diabetes Association.