Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Monsod, T. P.
Right arrow Articles by Tamborlane, W. V.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Monsod, T. P.
Right arrow Articles by Tamborlane, W. V.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Diabetes Care 25:889-893, 2002
© 2002 by the American Diabetes Association, Inc.


Pathophysiology/Complications
Original Article

Do Sensor Glucose Levels Accurately Predict Plasma Glucose Concentrations During Hypoglycemia and Hyperinsulinemia?

Teresa P. Monsod, MD1, Daniel E. Flanagan, MRCP3, Fran Rife, RN4, Rebecca Saenz, BS1, Sonia Caprio, MD1, Robert S. Sherwin, MD3 and William V. Tamborlane, MD1,2

1 Department of Pediatrics, Yale University School of Medicine, New Haven, Connecticut
2 Pediatric Pharmacology Research Unit, Yale University School of Medicine, New Haven, Connecticut
3 Department of Internal Medicine, Yale University School of Medicine, New Haven, Connecticut
4 General Clinical Research Centers, Yale University School of Medicine, New Haven, Connecticut

OBJECTIVE—The MiniMed Continuous Glucose Monitoring System (CGMS) measures subcutaneous interstitial glucose levels that are calibrated against three or more fingerstick glucose levels daily. The objective of the present study was to examine whether the relationship between plasma and interstitial fluid glucose is altered by changes in plasma glucose and insulin levels and how such alterations might influence CGMS performance.

RESEARCH DESIGN AND METHODS—Arterialized plasma glucose, sensor glucose, and interstitial fluid glucose were measured by microdialysis in 11 healthy subjects during a 1.0 mU · kg-1 · min-1 stepped euglycemic-hypoglycemic-hyperglycemic (plasma glucose ~5, 3.1, and 8.6 mmol/l, respectively) insulin clamp that raised plasma insulin to ~360–390 pmol/l.

RESULTS—When the CGMS was calibrated versus plasma glucose levels before insulin infusion, basal sensor and plasma glucose were similar (5.0 ± 0.3 vs. 5.2 ± 0.3 mmol/l, respectively); dialysate glucose was 3.3 ± 0.9 mmol/l. During the hyperinsulinemic-euglycemia study (plasma glucose 4.9 ± 0.3 mmol/l), dialysate glucose fell by 30–35%, accompanied by a significant reduction in sensor glucose (to 3.7 ± 0.6 mmol/l; P < 0.001 vs. plasma). Subsequently, sensor levels remained lower than plasma values during mild hypoglycemia (2.5 ± 0.6 vs. 3.1 ± 0.3 mmol/l; P < 0.01) and during recovery from hypoglycemia (7.3 ± 1.2 vs. 8.6 ± 0.6; P < 0.01). However, when the CGMS was calibrated against plasma glucose levels before and during each step of the clamp, sensor glucose levels increased throughout the study and did not differ from plasma glucose values during hypoglycemia.

CONCLUSIONS—Although hyperinsulinemia may contribute to modest discrepancies between plasma and sensor glucose levels, the CGMS is able to accurately track acute changes in plasma glucose when calibrated across a range of plasma glucose and insulin levels.

Abbreviations: ECF, extracellular fluid • CGMS, Continuous Glucose Monitoring System


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Diabetes CareHome page
P. G. McNally, J. D. Dean, A. D. Morris, P. D. Wilkinson, G. Compion, and S. R. Heller
Using Continuous Glucose Monitoring to Measure the Frequency of Low Glucose Values When Using Biphasic Insulin Aspart 30 Compared With Biphasic Human Insulin 30: A double-blind crossover study in individuals with type 2 diabetes
Diabetes Care, May 1, 2007; 30(5): 1044 - 1048.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
L. Allport, T. Baird, K. Butcher, L. MacGregor, J. Prosser, P. Colman, and S. Davis
Frequency and Temporal Profile of Poststroke Hyperglycemia Using Continuous Glucose Monitoring
Diabetes Care, August 1, 2006; 29(8): 1839 - 1844.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
M. Ellmerer, M. Haluzik, J. Blaha, J. Kremen, S. Svacina, W. Toller, J. Mader, L. Schaupp, J. Plank, and T. Pieber
Clinical Evaluation of Alternative-Site Glucose Measurements in Patients After Major Cardiac Surgery.
Diabetes Care, June 1, 2006; 29(6): 1275 - 1281.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
L. Monnier, E. Mas, C. Ginet, F. Michel, L. Villon, J.-P. Cristol, and C. Colette
Activation of Oxidative Stress by Acute Glucose Fluctuations Compared With Sustained Chronic Hyperglycemia in Patients With Type 2 Diabetes
JAMA, April 12, 2006; 295(14): 1681 - 1687.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
I. M. Wentholt, M. A. Vollebregt, A. A. Hart, J. B. Hoekstra, and J. H. DeVries
Comparison of a Needle-Type and a Microdialysis Continuous Glucose Monitor in Type 1 Diabetic Patients
Diabetes Care, December 1, 2005; 28(12): 2871 - 2876.
[Abstract] [Full Text] [PDF]


Home page
Clin. DiabetesHome page
P. Sapountzi, G. Charnogursky, M. A. Emanuele, D. Murphy, F. Nabhan, and N. V. Emanuele
Case Study: Diagnosis of Insulinoma Using Continuous Glucose Monitoring System in a Patient With Diabetes
Clin. Diabetes, July 1, 2005; 23(3): 140 - 143.
[Full Text] [PDF]


Home page
Diabetes CareHome page
T. Richardson, P. Thomas, J. Ryder, and D. Kerr
Influence of Caffeine on Frequency of Hypoglycemia Detected by Continuous Interstitial Glucose Monitoring System in Patients With Long-Standing Type 1 Diabetes
Diabetes Care, June 1, 2005; 28(6): 1316 - 1320.
[Abstract] [Full Text] [PDF]


Home page
Arch Intern MedHome page
A. R. Babu, J. Herdegen, L. Fogelfeld, S. Shott, and T. Mazzone
Type 2 Diabetes, Glycemic Control, and Continuous Positive Airway Pressure in Obstructive Sleep Apnea
Arch Intern Med, February 28, 2005; 165(4): 447 - 452.
[Abstract] [Full Text] [PDF]


Home page
Arch Pediatr Adolesc MedHome page
N. Weintrob, A. Schechter, H. Benzaquen, S. Shalitin, P. Lilos, A. Galatzer, and M. Phillip
Glycemic Patterns Detected by Continuous Subcutaneous Glucose Sensing in Children and Adolescents With Type 1 Diabetes Mellitus Treated by Multiple Daily Injections vs Continuous Subcutaneous Insulin Infusion
Arch Pediatr Adolesc Med, July 1, 2004; 158(7): 677 - 684.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
W. Regittnig, M. Ellmerer, G. Fauler, G. Sendlhofer, Z. Trajanoski, H.-J. Leis, L. Schaupp, P. Wach, and T. R. Pieber
Assessment of transcapillary glucose exchange in human skeletal muscle and adipose tissue
Am J Physiol Endocrinol Metab, August 1, 2003; 285(2): E241 - E251.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
C. Desouza, H. Salazar, B. Cheong, J. Murgo, and V. Fonseca
Association of Hypoglycemia and Cardiac Ischemia: A study based on continuous monitoring
Diabetes Care, May 1, 2003; 26(5): 1485 - 1489.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
A. Chico, P. Vidal-Rios, M. Subira, and A. Novials
The Continuous Glucose Monitoring System Is Useful for Detecting Unrecognized Hypoglycemias in Patients With Type 1 and Type 2 Diabetes but Is Not Better Than Frequent Capillary Glucose Measurements for Improving Metabolic Control
Diabetes Care, April 1, 2003; 26(4): 1153 - 1157.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
B. Guerci, M. Floriot, P. Bohme, D. Durain, M. Benichou, S. Jellimann, and P. Drouin
Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin Analogs
Diabetes Care, March 1, 2003; 26(3): 582 - 589.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
L. Monnier, H. Lapinski, and C. Colette
Contributions of Fasting and Postprandial Plasma Glucose Increments to the Overall Diurnal Hyperglycemia of Type 2 Diabetic Patients: Variations with increasing levels of HbA1c
Diabetes Care, March 1, 2003; 26(3): 881 - 885.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Endocrinol. Metab.Home page
D. E. Flanagan, M. L. Evans, T. P. Monsod, F. Rife, R. A. Heptulla, W. V. Tamborlane, and R. S. Sherwin
The influence of insulin on circulating ghrelin
Am J Physiol Endocrinol Metab, February 1, 2003; 284(2): E313 - E316.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
C. Choleau, P. Dokladal, J.-C. Klein, W. K. Ward, G. S. Wilson, and G. Reach
Prevention of Hypoglycemia Using Risk Assessment With a Continuous Glucose Monitoring System
Diabetes, November 1, 2002; 51(11): 3263 - 3273.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 2002 by the American Diabetes Association.