Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Erratum (v26,p553)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by McGowan, K.
Right arrow Articles by Moran, A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by McGowan, K.
Right arrow Articles by Moran, A.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Diabetes Care 25:1499-1503, 2002
© 2002 by the American Diabetes Association, Inc.


Clinical Care/Education/Nutrition
Original Article

Spurious Reporting of Nocturnal Hypoglycemia by CGMS in Patients With Tightly Controlled Type 1 Diabetes

Kilty McGowan1, William Thomas, PHD2 and Antoinette Moran, MD3

1 Como Park High School, Minneapolis, Minnesota
2 Department of Biostatistics, University of Minnesota, Minneapolis, Minnesota
3 Department of Pediatrics, University of Minnesota, Minneapolis, Minnesota

OBJECTIVE—The Medtronic MiniMed Continuous Glucose Monitoring System (CGMS) is designed to continuously monitor interstitial fluid glucose levels within a range of 40–400 mg/dl. It is considered an important tool for overnight glucose monitoring. The goal of this study was to determine the accuracy of this system in individuals with tightly controlled diabetes.

RESEARCH DESIGN AND METHODS—Seven adolescents and young adults with HbA1c levels 6.6 ± 0.6% (range 5.7–7.1) were admitted to the Clinical Research Center. Simultaneous glucose measurements obtained by glucose analyzer, Accu-Check Advantage meter, and CGMS were compared. The analyzer levels were considered the standard.

RESULTS—The CGMS results were lower than analyzer readings in 74% of simultaneous pairs of tests performed during the 24-h period; the average correlation was 0.76. There was a trend for the poorest correlation to occur in patients with the narrowest range in daily glucose levels. When the lowest CGMS reading of the night was compared with the simultaneous analyzer reading, the CGMS level was lower in all cases by an average of 38 ± 15%. In six of seven patients, the discrepancy was believed to be clinically significant; in at least four patients, overnight glucose levels reported by CGMS were falsely low, in a range that might have resulted in inappropriate reduction of overnight insulin dose.

CONCLUSIONS—CGMS reports of asymptomatic nighttime hypoglycemia may be spurious and should be interpreted with caution in patients with tightly controlled diabetes.

Abbreviations: CGMS, Continuous Glucose Monitoring System


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Diabetes CareHome page
R. L. Weinstein, S. L. Schwartz, R. L. Brazg, J. R. Bugler, T. A. Peyser, and G. V. McGarraugh
Accuracy of the 5-Day FreeStyle Navigator Continuous Glucose Monitoring System: Comparison with frequent laboratory reference measurements
Diabetes Care, May 1, 2007; 30(5): 1125 - 1130.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
D. M. Wilson, R. W. Beck, W. V. Tamborlane, M. J. Dontchev, C. Kollman, P. Chase, L. A. Fox, K. J. Ruedy, E. Tsalikian, S. A. Weinzimer, et al.
The Accuracy of the FreeStyle Navigator Continuous Glucose Monitoring System in Children With Type 1 Diabetes
Diabetes Care, January 1, 2007; 30(1): 59 - 64.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
R. P. Radermecker
Intensive Insulin Therapy in the Intensive Care Unit: Assessment by Continuous Glucose Monitoring: Response to De Block et al.
Diabetes Care, December 1, 2006; 29(12): 2762 - 2763.
[Full Text] [PDF]


Home page
Diabetes CareHome page
L. Allport, T. Baird, K. Butcher, L. MacGregor, J. Prosser, P. Colman, and S. Davis
Frequency and Temporal Profile of Poststroke Hyperglycemia Using Continuous Glucose Monitoring
Diabetes Care, August 1, 2006; 29(8): 1839 - 1844.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
K. Yates, A. Hasnat Milton, K. Dear, and G. Ambler
Continuous Glucose Monitoring-Guided Insulin Adjustment in Children and Adolescents on Near-Physiological Insulin Regimens: A randomized controlled trial
Diabetes Care, July 1, 2006; 29(7): 1512 - 1517.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
I. M. Wentholt, M. A. Vollebregt, A. A. Hart, J. B. Hoekstra, and J. H. DeVries
Comparison of a Needle-Type and a Microdialysis Continuous Glucose Monitor in Type 1 Diabetic Patients
Diabetes Care, December 1, 2005; 28(12): 2871 - 2876.
[Abstract] [Full Text] [PDF]


Home page
Clin. DiabetesHome page
P. Sapountzi, G. Charnogursky, M. A. Emanuele, D. Murphy, F. Nabhan, and N. V. Emanuele
Case Study: Diagnosis of Insulinoma Using Continuous Glucose Monitoring System in a Patient With Diabetes
Clin. Diabetes, July 1, 2005; 23(3): 140 - 143.
[Full Text] [PDF]


Home page
Diabetes CareHome page
T. Richardson, P. Thomas, J. Ryder, and D. Kerr
Influence of Caffeine on Frequency of Hypoglycemia Detected by Continuous Interstitial Glucose Monitoring System in Patients With Long-Standing Type 1 Diabetes
Diabetes Care, June 1, 2005; 28(6): 1316 - 1320.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
The Diabetes Research in Children Network (DirecNe
Eight-Point Glucose Testing Versus the Continuous Glucose Monitoring System in Evaluation of Glycemic Control in Type 1 Diabetes
J. Clin. Endocrinol. Metab., June 1, 2005; 90(6): 3387 - 3391.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
D. C. Klonoff
Continuous Glucose Monitoring: Roadmap for 21st century diabetes therapy
Diabetes Care, May 1, 2005; 28(5): 1231 - 1239.
[Full Text] [PDF]


Home page
J. Nutr.Home page
A. G. Pittas, R. Hariharan, P. C. Stark, C. L. Hajduk, A. S. Greenberg, and S. B. Roberts
Interstitial Glucose Level Is a Significant Predictor of Energy Intake in Free-Living Women with Healthy Body Weight
J. Nutr., May 1, 2005; 135(5): 1070 - 1074.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
G. S. Jeha, L. P. Karaviti, B. Anderson, E. O'Brian Smith, S. Donaldson, T. S. McGirk, and M. W. Haymond
Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes
Diabetes Care, December 1, 2004; 27(12): 2881 - 2886.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
Accuracy of the GlucoWatch G2 Biographer and the Continuous Glucose Monitoring System During Hypoglycemia: Experience of the Diabetes Research in Children Network
Diabetes Care, March 1, 2004; 27(3): 722 - 726.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
M. S. Boyne, D. M. Silver, J. Kaplan, and C. D. Saudek
Timing of Changes in Interstitial and Venous Blood Glucose Measured With a Continuous Subcutaneous Glucose Sensor
Diabetes, November 1, 2003; 52(11): 2790 - 2794.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
P. E. Cryer, S. N. Davis, and H. Shamoon
Hypoglycemia in Diabetes
Diabetes Care, June 1, 2003; 26(6): 1902 - 1912.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
C. Desouza, H. Salazar, B. Cheong, J. Murgo, and V. Fonseca
Association of Hypoglycemia and Cardiac Ischemia: A study based on continuous monitoring
Diabetes Care, May 1, 2003; 26(5): 1485 - 1489.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
M. Metzger, G. Leibowitz, J. Wainstein, B. Glaser, and I. Raz
Response to Mastrototaro and Gross
Diabetes Care, January 1, 2003; 26(1): 256 - 257.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 2002 by the American Diabetes Association.