Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Guerci, B.
Right arrow Articles by Drouin, P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Guerci, B.
Right arrow Articles by Drouin, P.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Diabetes Care 26:582-589, 2003
© 2003 by the American Diabetes Association, Inc.


Clinical Care/Education/Nutrition
Original Article

Clinical Performance of CGMS in Type 1 Diabetic Patients Treated by Continuous Subcutaneous Insulin Infusion Using Insulin Analogs

Bruno Guerci, MD, PHD, Michèle Floriot, MD, Philip Böhme, MD, Danielle Durain, RN, Muriel Benichou, MD, Stéphanie Jellimann, MD and Pierre Drouin, MD*,

Service de Diabétologie, Maladies Métaboliques et Maladies de la Nutrition, Centre d’Investigation Clinique-INSERM/CHU de NANCY-Hôpital Jeanne d’Arc, Centre Hospitalo-Universitaire de Nancy, Toul cedex, France

OBJECTIVE—Performance criteria have been established for in vitro blood glucose monitoring, particularly for the self-monitoring of blood glucose using glucose meters. Devices intended for use in the future, such as the continuous glucose monitoring system (CGMS), should satisfy similar criteria, particularly in diabetic patients under intensive therapy.

RESEARCH DESIGN AND METHODS—The analysis was conducted on 18 type 1 diabetic patients (not controlled, HbA1c >7.5%) treated by external pump using insulin analogs. Each patient received a glucose sensor for 3 days during his/her hospitalization and was instructed in its operation. Medtronic criteria were used to determine the accuracy of the CGMS. In addition, the data were analyzed according to American Diabetes Association (ADA) criteria, Clarke Error Grid analysis, and method of residuals, with the glucose oxidase method using a Beckman analyzer used as the reference method. Specificity and sensitivity were evaluated from the viewpoint of accuracy in the detection of hypoglycemia. For nine patients, two glucose sensors were simultaneously inserted into an abdominal site to determine the reproducibility of the system.

RESULTS—Among the 33 glucose sensors inserted, 6 (18%) were nonfunctional. The mean duration of CGMS recording was 63 ± 12 h. From all of the 692 sets of data that paired glucose readings and CGMS, the coefficients of correlation ranged from 0.87 to 0.92 and the mean absolute error ranged from 12.8 to 15.7%. The time experienced in hypoglycemia (<55 mg/dl) was reported at 86 ± 62 min/day. Only 39% of the CGMS values satisfied the ADA precision criteria to within ±10%, and 19% of these values satisfied the future ADA precision criteria of accuracy to within ±5%. The means of difference method showed that the CGMS slightly underestimated the plasma glucose values (mean = -12 mg/dl). Error grid analysis showed only 77% of the glucose sensor values were in zone A, and 98.9% were in zones A and B. Two values fell in zone C and a single value fell in zone D. The sensitivity and specificity of the CGMS to detect hypoglycemia were 33 and 96%, respectively. A total of 6,666 paired sensor values were recorded with a coefficient of correlation of 0.84 with a coefficient of variation of 8.25%.

CONCLUSIONS—CGMS could be useful in routine clinical practice to provide much more information on the glucose profile than intermittent self-monitoring of blood glucose (SMBG). However, CGMS cannot be used as a replacement for glucose meters because it does not satisfy the conventional performance goals set down for in vitro glucose measurements and could therefore lead to clinically incorrect treatment decisions.

Abbreviations: ADA, American Diabetes Association • CGMS, continuous glucose monitoring system • FN, false negative • FP, false positive • SMBG, self-monitoring of blood glucose • TN, true negative • TP, true positive


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Diabetes Spectr.Home page
M. R. Burge, S. Mitchell, A. Sawyer, and D. S. Schade
Continuous Glucose Monitoring: The Future of Diabetes Management
Diabetes Spectr, April 1, 2008; 21(2): 112 - 119.
[Abstract] [Full Text] [PDF]


Home page
PediatricsHome page
H. G. Piper, J. L. Alexander, A. Shukla, F. Pigula, J. M. Costello, P. C. Laussen, T. Jaksic, and M. S.D. Agus
Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery
Pediatrics, September 1, 2006; 118(3): 1176 - 1184.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
K. Yates, A. Hasnat Milton, K. Dear, and G. Ambler
Continuous Glucose Monitoring-Guided Insulin Adjustment in Children and Adolescents on Near-Physiological Insulin Regimens: A randomized controlled trial
Diabetes Care, July 1, 2006; 29(7): 1512 - 1517.
[Abstract] [Full Text] [PDF]


Home page
JAMAHome page
L. Monnier, E. Mas, C. Ginet, F. Michel, L. Villon, J.-P. Cristol, and C. Colette
Activation of Oxidative Stress by Acute Glucose Fluctuations Compared With Sustained Chronic Hyperglycemia in Patients With Type 2 Diabetes
JAMA, April 12, 2006; 295(14): 1681 - 1687.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
I. M. Wentholt, M. A. Vollebregt, A. A. Hart, J. B. Hoekstra, and J. H. DeVries
Comparison of a Needle-Type and a Microdialysis Continuous Glucose Monitor in Type 1 Diabetic Patients
Diabetes Care, December 1, 2005; 28(12): 2871 - 2876.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
D. C. Klonoff
Continuous Glucose Monitoring: Roadmap for 21st century diabetes therapy
Diabetes Care, May 1, 2005; 28(5): 1231 - 1239.
[Full Text] [PDF]


Home page
Diabetes CareHome page
G. S. Jeha, L. P. Karaviti, B. Anderson, E. O'Brian Smith, S. Donaldson, T. S. McGirk, and M. W. Haymond
Continuous Glucose Monitoring and the Reality of Metabolic Control in Preschool Children With Type 1 Diabetes
Diabetes Care, December 1, 2004; 27(12): 2881 - 2886.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
Accuracy of the GlucoWatch G2 Biographer and the Continuous Glucose Monitoring System During Hypoglycemia: Experience of the Diabetes Research in Children Network
Diabetes Care, March 1, 2004; 27(3): 722 - 726.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 2003 by the American Diabetes Association.