Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lewanczuk, R. Z.
Right arrow Articles by Toth, E. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lewanczuk, R. Z.
Right arrow Articles by Toth, E. L.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Diabetes Care 27:441-447, 2004
© 2004 by the American Diabetes Association, Inc.


Emerging Treatments and Technologies
Original Article

Comparison of the [13C]Glucose Breath Test to the Hyperinsulinemic-Euglycemic Clamp When Determining Insulin Resistance

Richard Z. Lewanczuk, MD, PHD, Breay W. Paty, MD and Ellen L. Toth, MD

From the Division of Endocrinology, University of Alberta, Edmonton, Canada

Address correspondence and reprint requests to Dr. Richard Lewanczuk, Division of Endocrinology, 362 HMRC, University of Alberta, Edmonton, Alberta, Canada T6G 2S2. E-mail: rlewancz{at}gpu.srv.ualberta.ca

OBJECTIVE—With increasing emphasis on the recognition of the metabolic syndrome and early type 2 diabetes, a clinically useful measure of insulin resistance is desirable. The purpose of this study was to evaluate whether an index of glucose metabolism, as measured by 13CO2 generation from ingested [13C]glucose, would correlate with indexes from the hyperinsulinemic-euglycemic clamp.

RESEARCH DESIGN AND METHODS—A total of 26 subjects with varying degrees of insulin sensitivity underwent both the [13C]glucose breath test and the hyperinsulinemic-euglycemic clamp. Results from the [13C]glucose breath test were compared with measures of insulin sensitivity from the glucose clamp as well as with other commonly used indexes of insulin sensitivity.

RESULTS—There was a strong correlation between the [13C]glucose breath test result and the glucose disposal rate (r = 0.69, P < 0.0001) and insulin sensitivity index (r = 0.69, P < 0.0001) from the insulin clamp. The magnitude of these correlations compared favorably with QUICKI and were superior to the homeostasis model assessment.

CONCLUSIONS—The [13C]glucose breath test may provide a useful noninvasive assessment of insulin sensitivity.

Abbreviations: ADA, American Diabetes Association • HOMA, homeostasis model assessment • ISI, insulin sensitivity index • QUICKI, quantitative insulin sensitivity check index


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Diabetes CareHome page
C. Beysen, E. J. Murphy, T. McLaughlin, T. Riiff, C. Lamendola, H. C. Turner, M. Awada, S. M. Turner, G. Reaven, and M. K. Hellerstein
Whole-Body Glycolysis Measured by the Deuterated-Glucose Disposal Test Correlates Highly With Insulin Resistance In Vivo