Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Service, F. J.
Right arrow Articles by Gerich, J. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Service, F. J.
Right arrow Articles by Gerich, J. E.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 3, Issue 2 278-284, Copyright © 1980 by American Diabetes Association


ARTICLES

Considerations for the programming of an open-loop insulin infusion device from the biostator glucose controller

FJ Service, RA Rizza, RE Westland, LD Hall, RL Nelson, MW Haymond, AH Clemens and JE Gerich

To assess the feasibility of preprogramming an open-loop device with insulin flow rates generated by the Biostator Glucose Controller, comparisons were made in 10 juvenile-onset diabetic patients between meals of equal size and composition taken in the morning, at noon, and in the evening and a bedtime snack during a 24-h period of Biostator glucose control. Four additional diabetic patients had Biostator glucose control for 72 h. Similar amounts of insulin were infused for the meals taken at differing times of the day and, except for the morning meal, for the same meal on two successive days. The meal-related glycemic patterns expressed as mean indices of meal excursions (MIME) were similar for meals of identical size and composition during a single day and for the same meal taken on two consecutive days. Preliminary results using an open-loop device preprogrammed by the Biostator system, although encouraging, underscore the deficiency of the subcutaneous route viz. the delayed entry of insulin into the circulation in achieving normal glucose levels and patterns.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?





HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1980 by the American Diabetes Association.