Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ferguson, R. T.
Right arrow Articles by Albisser, A. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ferguson, R. T.
Right arrow Articles by Albisser, A. M.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 3, Issue 2 332-337, Copyright © 1980 by American Diabetes Association


ARTICLES

Electronic flow rate controller for a portable insulin infusion pump

RT Ferguson, B Zinman, EB Marliss and AM Albisser

An electronic controller is described that regulates the flow of infusate by controlling the fraction of time that a pump is energized. Using the integral programming capability of the device, any one of 256 possible basal rates between 0 and 49.6% of the maximum rate can be chosen. An externally triggerable single meal-associated pulse can also be configured. The rate during the meal pulse can be any one of the 255 equally spaced rates in the range of 0--99.7%. The duration of this pulse can be chosen in 3-min steps to a maximum of 12.75 h, after which the rate automatically returns to the basal value. The controller consumes a minimum amount of power and can continuously operate a dc motor-driven pump at 3.0 V for 36 h. It drives the pump in an on-off mode in order to control the average flow rate digitally. In this way a significant reduction in the power requirements is realized and the system can be run for many days using small rechargeable batteries. One year of experience with 20 of these controllers was obtained in the research laboratory and clinical investigation unit. The results of this experience indicated the reliability and precision of these controllers, gave insight into their modes of failure, and provided valuable biomedical data for their improvement.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?