Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Buchwald, H.
Right arrow Articles by Varco, R. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Buchwald, H.
Right arrow Articles by Varco, R. L.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Diabetes Care, Vol 3, Issue 2 351-358, Copyright © 1980 by American Diabetes Association


ARTICLES

A totally implantable drug infusion defice: laboratory and clinical experience using a model with single flow rate and new design for modulated insulin infusion

H Buchwald, TD Rohde, FD Dorman, JG Skakoon, BD Wigness, FR Prosl, EM Tucker, TG Rublein, PJ Blackshear and RL Varco

The Infusaid implantable infusion pump with a single delivery rate has maintained chronic intravenous heparin infusion in man for greater than 35 mo and for greater than 5 yr in the dog. Intra-arterial infuson of fluorodeoxyuridine has been maintained for greater than 8 mo in man. In a pilot study using a commercially available, transcutaneously controllable, magnetically activated valve for baseline superimposed bolus insulin infusion, the feasibility of maintaining near normal serum glucose in diabetic dogs was demonstrated. The effect of long-term intravenous cannulation was investigated; it was found that the intimal tissues of the vena cava surrounding the cannulae were largely unaltered and microemboli could not be detected in the lungs of the animals studied. Cannula plugging, which occurred on several occasions due to thrombus formation in the final centimeter of the cannula, has been solved by changes in pump design and refilling procedures. The problem of insulin precipitation in flow passages of the pump remains unsolved, but there are indications that substances entering the cannula from the blood may be involved. A new pump design for modulated insulin infusion is described.
Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
The Diabetes EducatorHome page
R. Farkas-Hirsch and Lucya. Levandoski
Implementation of Continuous Subcutaneous Insulin Infusion Therapy: An Overview
The Diabetes Educator, January 1, 1988; 14(5): 401 - 406.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 1980 by the American Diabetes Association.