Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Diabetes Care 30:59-64, 2007
DOI: 10.2337/dc06-1407
© 2007 by the American Diabetes Association
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Wilson, D. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wilson, D. M.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Emerging Treatments and Technologies
Original Article

The Accuracy of the FreeStyle Navigator Continuous Glucose Monitoring System in Children With Type 1 Diabetes

Darrell M. Wilson, MD, Roy W. Beck, MD, PHD, William V. Tamborlane, MD, Mariya J. Dontchev, MPH, Craig Kollman, PHD, Peter Chase, MD, Larry A. Fox, MD, Katrina J. Ruedy, MSPH, Eva Tsalikian, MD, Stuart A. Weinzimer, MD and the DirecNet Study Group

From the DirecNet Coordinating Center, Jaeb Center for Health Research, Tampa, Florida

Address correspondence and reprint requests to Darrell M. Wilson, MD, DirecNet Coordinating Center, Jaeb Center for Health Research, 15310 Amberly Dr., Suite 350, Tampa, FL 33647. E-mail: direcnet{at}jaeb.org

OBJECTIVE—To evaluate the accuracy and precision of the FreeStyle Navigator continuous glucose monitoring system in children with type 1 diabetes.

RESEARCH DESIGN AND METHODS—In 30 children with type 1 diabetes (mean age 11.2 ± 4.1 years), the Navigator glucose values were compared with reference serum glucose values of blood samples obtained in an inpatient clinical research center and measured in a central laboratory using a hexokinase enzymatic method and in an outpatient setting with a FreeStyle meter. Median absolute difference (AD) and median relative absolute difference (RAD) were computed for sensor-reference and sensor-sensor pairs.

RESULTS—The median AD and RAD were 17 mg/dl and 12%, respectively, for 1,811 inpatient sensor-reference pairs and 20 mg/dl and 14%, respectively, for 8,639 outpatient pairs. The median RAD between two simultaneous Navigator measurements (n = 1,971) was 13%. Ninety-one percent of sensors in the inpatient setting and 81% of sensors in the outpatient setting had a median RAD ≤20%.

CONCLUSIONS—The Navigator’s accuracy does not yet approach the accuracy of current-generation home glucose meters, but it is sufficient to believe that the device has the potential to be an important adjunct to treatment of youth with type 1 diabetes.

Abbreviations: AD, absolute difference • CGMS, continuous glucose monitoring system • CRC, clinical research center • ISO, International Organisation for Standardization • RAD, relative absolute difference


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
NEJMHome page
The Juvenile Diabetes Research Foundation Continuo
Continuous Glucose Monitoring and Intensive Treatment of Type 1 Diabetes
N. Engl. J. Med., October 2, 2008; 359(14): 1464 - 1476.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. A. Weinzimer, G. M. Steil, K. L. Swan, J. Dziura, N. Kurtz, and W. V. Tamborlane
Fully Automated Closed-Loop Insulin Delivery Versus Semiautomated Hybrid Control in Pediatric Patients With Type 1 Diabetes Using an Artificial Pancreas
Diabetes Care, May 1, 2008; 31(5): 934 - 939.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
E. Dassau, B. W. Bequette, B. A. Buckingham, and F. J. Doyle III
Detection of a Meal Using Continuous Glucose Monitoring: Implications for an artificial {beta}-cell
Diabetes Care, February 1, 2008; 31(2): 295 - 300.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
Z. T. Bloomgarden
Type 1 Diabetes and Glucose Monitoring
Diabetes Care, November 1, 2007; 30(11): 2965 - 2971.
[Full Text] [PDF]


Home page
Obstet GynecolHome page
Continuous Glucose Monitoring
Obstet. Gynecol., July 1, 2007; 110(1): 175 - 177.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum
Copyright © 2007 by the American Diabetes Association.