Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


Diabetes Care 30:2756-2758, 2007
DOI: 10.2337/dc07-1301
© 2007 by the American Diabetes Association
This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Cohen, R. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Cohen, R. M.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?

Editorials

A1C: Does One Size Fit All?

Robert M. Cohen, MD

From the Division of Endocrinology, Metabolism, and Diabetes, Department of Medicine, University of Cincinnati, Cincinnati, Ohio; and Medical Service, Cincinnati Veterans Affairs Medical Center, Cincinnati, Ohio

Address correspondence to Robert M. Cohen, MD, University of Cincinnati Medical Center, P.O. Box 670547, Cincinnati, OH 45267-0547. E-mail: robert.cohen@uc.edu

The first 300 words of the full text of this article appear below.

Diabetes specialists almost uniformly nod their heads when I ask whether they see patients whose A1C results don't match their blood glucose monitoring data. Providers used to attribute that to unreliability of the monitors or the patient records, but technological advances overcame those barriers. Some mismatches can be attributed to inadequate temporal distribution of glucose sampling, and those will be easier to define as continuous glucose monitoring is used more widely, but a substantial number still remain unexplained. That has led to a controversy as to the role of remaining sources of variation in A1C in the routine patient in whom there is no obvious condition known to influence A1C values, i.e., hemoglobinopathy, red cell disorder, or renal failure known to alter either mean age of circulating red cells or hemoglobin chromatographic properties; or the rare drug that modifies A1C by a variety of mechanisms. Without such pathology, does the fact that such variation remains suggest that our standard A1C goals for glycemic control do not in fact fit all individuals with diabetes? Is it indeed valid to equate A1C and mean blood glucose as has become common?

There is one view that proposes a "high glycator–low glycator" hypothesis (1–9) to explain how apparently equivalent glycemic control could result in differing A1C values. The hypothesis is based on the observation that while most individuals in a population with a given mean blood glucose will have A1C within a fairly narrow expected range, there are subsets who have a consistently higher or consistently lower value. These could be due to corresponding alterations either in the relative rate of intracellular glycation or deglycation or in the rate of hemoglobin (red cell) turnover. How large a problem does this have to be to have widespread clinical implications? Even if . . . [Full Text of this Article]


Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
BloodHome page
R. M. Cohen, R. S. Franco, P. K. Khera, E. P. Smith, C. J. Lindsell, P. J. Ciraolo, M. B. Palascak, and C. H. Joiner
Red cell life span heterogeneity in hematologically normal people is sufficient to alter HbA1c
Blood, November 15, 2008; 112(10): 4284 - 4291.
[Abstract] [Full Text] [PDF]


Home page
DiabetesHome page
P. K. Khera, C. H. Joiner, A. Carruthers, C. J. Lindsell, E. P. Smith, R. S. Franco, Y. R. Holmes, and R. M. Cohen
Evidence for Interindividual Heterogeneity in the Glucose Gradient Across the Human Red Blood Cell Membrane and Its Relationship to Hemoglobin Glycation
Diabetes, September 1, 2008; 57(9): 2445 - 2452.
[Abstract] [Full Text] [PDF]


Home page
Ann Clin BiochemHome page
D. R Macdonald, A. M Hanson, M. R Holland, and B. M Singh
Clinical impact of variability in HbA1c as assessed by simultaneously measuring fructosamine and use of error grid analysis
Ann Clin Biochem, July 1, 2008; 45(4): 421 - 425.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Endocrinol. Metab.Home page
C. D. Saudek, W. H. Herman, D. B. Sacks, R. M. Bergenstal, D. Edelman, and M. B. Davidson
A New Look at Screening and Diagnosing Diabetes Mellitus
J. Clin. Endocrinol. Metab., July 1, 2008; 93(7): 2447 - 2453.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum