Diabetes Care
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jungheim, K.
Right arrow Articles by Koschinsky, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jungheim, K.
Right arrow Articles by Koschinsky, T.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?
Diabetes Care 24:1303-1304, 2001
© 2001 by the American Diabetes Association, Inc.


Letters: Observations
Letter

Risky Delay of Hypoglycemia Detection by Glucose Monitoring at the Arm

Karsten Jungheim and Theodor Koschinsky, MD

Clinical Department, German Diabetes Research Institute, Heinrich-Heine University of Duesseldorf, Duesseldorf, Germany

Several devices for self-monitoring of blood glucose (SMBG) (e.g., AtLast, Amira; OneTouch Ultra, LifeScan; FreeStyle, TheraSense, Alameda, CA; Glucometer-Elite XL+Microlet-Vaculance, Bayer; and Sof-Tact, Abbott) recently received Food and Drug Administration approval for alternative site monitoring of capillary blood glucose. These alternatives are marketed with considerable efforts under the assumption that capillary blood glucose measurements, e.g., those taken at the forearm, do not differ from the results obtained by classic finger pricking. Diabetic patients using different devices for SMBG reported discrepancies between clinical symptoms of hypoglycemia and normoglycemic SMBG values at the forearm. Neither standardized quality control assessments of technical performance of such SMBG devices (1,2) nor patient device handling resulted in any obvious explanation of the reported discrepancies. Because of this, we examined whether or not fast blood glucose changes over a larger range of blood glucose concentrations could result in clinically relevant blood glucose differences between forearm and fingertip.

Capillary blood glucose samples were taken from the fingertip and the forearm of six male type 1 diabetic patients on intensified insulin treatment (age 26–54 years, diabetes duration 0.1–25 years) using the FreeStyle system (TheraSense) because it required the smallest blood glucose amount: 0.3 µl/sample. To avoid any disturbance of the normal regional blood flow, the forearm skin was not rubbed before blood glucose sampling, as recommended by the manufacturer. The following protocol was applied: after an overnight fast the usual prebreakfast insulin was omitted and the breakfast was replaced by oral Dextro O.G.T. (Roche, Mannheim, Germany), equivalent to 75 g glucose, in order to achieve blood glucose values of 300–400 mg/dl. Then the patient’s usual short-acting insulin was given intravenously at an individual dose (6–15 U/injection). The blood glucose decrease was followed every 5–15 min until either steady state or hypoglycemia (<60 mg/dl) was reached. Hypoglycemia was compensated by oral glucose. For control purposes, additional blood glucose samples from the fingertip were analyzed by the Gluco-quant method (Roche, Mannheim, Germany).

The capillary blood glucose decrease (mean ± SD) at the forearm (208 ± 38 mg/dl) was significantly smaller than at the fingertip (295 ± 16 mg/dl) (Student’s paired t test: P < 0.01) within 111 ± 26 min for all patients. An example is shown in Fig. 1. For the two patients with hypoglycemic unawareness, the first asymptomatic hypoglycemic values at the fingertip (51 and 53 mg/dl) were accompanied by normoglycemic values at the forearm (142 and 159 mg/dl). Compared with the fingertip, it took an additional 27–34 min until the capillary blood glucose levels at the forearm reached hypoglycemic values.



View larger version (14K):
[in this window]
[in a new window]
 
Figure 1 — Effect of a fast blood glucose decrease (3 mg · dl-1 · min) on capillary blood glucose values at the fingertip (•) and at the forearm ({circ}) using the FreeStyle system in a type 1 diabetic patient. Control blood glucose values from the fingertip measured at the laboratory are indicated ({triangleup}).

 
Despite the preliminary state of our investigation, the consistency of clinically relevant delays of blood glucose changes at the forearm prompted us to draw attention to a potentially very dangerous situation. Our results raise the possibility that the delayed glucose concentration changes at the forearm occur physiologically. To our knowledge, this has not been fully recognized as a potential problem by the certifying administrations in the U.S. or Europe.

Even a few delays of hypoglycemia detection could unnecessarily endanger the life of diabetic patients. Because of this, we strongly recommend providing sufficient evidence that the suggested use of SMBG at the forearm and other alternative sites does not result in a risky delay of hypoglycemia detection. Meanwhile, SMBG at the forearm should only be used when ongoing fast blood glucose changes can be excluded.

FOOTNOTES

Address correspondence to Theodor Koschinsky, MD, Auf’m Hennekamp 65, D-40225 Duesseldorf, Germany. E-mail: koschins{at}neuss.netsurf.de.

References

  1. Koschinsky T, Dannehl K, Gries FA: New approach to technical and clinical evaluation of devices for self-monitoring of blood glucose. Diabetes Care 11:619–629, 1988[Abstract]
  2. Koschinsky T, Heidkamp P, Vogt H: FreeStyle: technical evaluation of a new blood glucose meter for off-finger testing (Abstract). Diabetes 49(Suppl. 1):A114, 2000

Add to CiteULike CiteULike   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati    What's this?


This article has been cited by other articles:


Home page
Diabetes CareHome page
I. M. Wentholt, M. A. Vollebregt, A. A. Hart, J. B. Hoekstra, and J. H. DeVries
Comparison of a Needle-Type and a Microdialysis Continuous Glucose Monitor in Type 1 Diabetic Patients
Diabetes Care, December 1, 2005; 28(12): 2871 - 2876.
[Abstract] [Full Text] [PDF]


Home page
Diabetes CareHome page
S. Meguro, O. Funae, K. Hosokawa, and Y. Atsumi
Hypoglycemia Detection Rate Differs Among Blood Glucose Monitoring Sites
Diabetes Care, March 1, 2005; 28(3): 708 - 709.
[Full Text] [PDF]


Home page
Diabetes CareHome page
N. Lucidarme, C. Alberti, I. Zaccaria, E. Claude, and N. Tubiana-Rufi
Alternate-Site Testing Is Reliable in Children and Adolescents With Type 1 Diabetes, Except at the Forearm for Hypoglycemia Detection
Diabetes Care, March 1, 2005; 28(3): 710 - 711.
[Full Text] [PDF]


Home page
Journal of Pharmacy PracticeHome page
G. Vincze and A. Parthan
The Value of Home Monitoring Kits in Diabetes, Hypertension, Asthma, and Oral Anticoagulation Therapy
Journal of Pharmacy Practice, June 1, 2004; 17(3): 182 - 196.
[Abstract] [PDF]


Home page
Diabetes CareHome page
K. Arimoto, H. Sasaki, K. Ogawa, H. Yamasaki, K. Okamoto, H. Furuta, T. Hanabusa, M. Nishi, T. Nakao, and K. Nanjo
Negative Pressure Suction During Blood Sampling May Reduce the Difference in Self-Monitoring of Blood Glucose Results Between Fingertip Pricking and Forearm Pricking
Diabetes Care, June 1, 2004; 27(6): 1449 - 1450.
[Full Text] [PDF]


Home page
Journal of Pharmacy PracticeHome page
A. L. Briggs and S. Cornell
Self-monitoring Blood Glucose (SMBG): Now and the Future
Journal of Pharmacy Practice, February 1, 2004; 17(1): 29 - 38.
[Abstract] [PDF]


Home page
Diabetes CareHome page
D. M. Bina, R. L. Anderson, M. L. Johnson, R. M. Bergenstal, and D. M. Kendall
Clinical Impact of Prandial State, Exercise, and Site Preparation on the Equivalence of Alternative-Site Blood Glucose Testing
Diabetes Care, April 1, 2003; 26(4): 981 - 985.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow Full Text (PDF)
Right arrow Purchase Article
Right arrow View Shopping Cart
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Download to citation manager
Right arrow Request Permissions
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jungheim, K.
Right arrow Articles by Koschinsky, T.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jungheim, K.
Right arrow Articles by Koschinsky, T.
Social Bookmarking
 Add to CiteULike   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati  
What's this?


HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
Diabetes Diabetes Care Clinical Diabetes Diabetes Spectrum