© 2005 by the American Diabetes Association, Inc.
Dose Response of Inhaled Dry-Powder Insulin and Dose Equivalence to Subcutaneous Insulin Lispro
1 Profil Institut für Stoffwechselforschung, Neuss, Germany Address correspondence and reprint requests to Klaus Rave, MD, Profil Institut für Stoffwechselforschung, Hellersbergstr. 9, D-41460 Neuss, Germany. E-mail: klaus.rave{at}profil-research.de
OBJECTIVETo determine the pharmacokinetic (PK) and glucodynamic (GD) dose response of human insulin inhalation powder (HIIP) delivered via AIR particle technology and dose equivalence to subcutaneous (SC) insulin lispro. RESEARCH DESIGN AND METHODSTwenty healthy, nonsmoking, male or female subjects (aged 29.6 ± 6.9 years, BMI 23.2 ± 2.3 kg/m2, means ± SD) with normal forced vital capacity and forced expiratory volume were enrolled in an open-label, randomized, seven-period, euglycemic glucose clamp, cross-over trial. Each subject received up to four single doses of HIIP (2.6, 3.6, 5.2, or 7.8 mg) and three doses of SC lispro (6, 12, or 18 units) from 5 to 18 days apart. RESULTSHIIP demonstrated a similar rapid onset but an extended time exposure and a prolonged duration of effect (late t50% 412 vs. 236 min, P < 0.001) compared with SC lispro. The HIIP versus SC lispro doses of 2.6 mg vs. 6 units, 5.2 mg vs. 12 units, and 7.8 mg vs. 18 units achieved similar PK area under the serum immunoreactive insulin (IRI) concentration-versus-time curve from time zero until the serum IRI concentrations returned to the predose baseline value [AUC(0-t')] and GD (Gtot) responses. The median insulin (tmax) was not different between HIIP and SC lispro (45 min for both), although the median time of return to baseline for PK was apparently longer for HIIP compared with SC lispro (480 vs. 360 min). Relative bioavailability and relative biopotency of HIIP were consistent across doses (8 and 9%). CONCLUSIONSWhile the time-action profile was longer for HIIP than for SC lispro, both treatments showed rapid initial absorption and similar overall PK exposure and GD effect. HIIP was as well tolerated as SC lispro, thereby offering a promising alternative to injectable insulin therapy.
Abbreviations: AUC, area under the curve FEV, forced expiratory volume FVC, forced vital capacity GD, glucodynamic GIR, glucose infusion rate HIIP, human insulin inhalation powder IRI, immunoreactive insulin PK, pharmacokinetic SC, subcutaneous
The disease burden of diabetes continues to grow and currently affects >18 million Americans and their families (1). Despite increased use of diabetes medications (without, however, increased utilization of insulin), overall diabetes control A1C among individuals diagnosed with diabetes in the U.S. has not improved, with A1C rising from 7.7 to 7.9% during the final decade of the last century (2). These data emphasize a need for alternative diabetes therapies with earlier more physiologic use of insulin. The delivery of insulin by the lung may provide an attractive alternative for many patients with diabetes (38). However, alternative insulin delivery systems must meet certain pharmacokinetic (PK) and glucodynamic (GD) requirements to reach maximum utility (9). Specifically, the dose-response characteristics of inhaled insulin should be similar to those of injectable insulins, like human regular insulin or fast-acting insulin analogs such as insulin lispro. Moreover, inhaled insulin should demonstrate satisfactory dose reproducibility; that is, intrasubject variability of inhaled insulin should be similar to or better than that of injectable insulin. Finally, the ratio of dose equivalence between inhaled insulin and injectable insulin ought to be consistent across a range of doses. The present study evaluated the key performance features of a novel inhaled insulin delivery system based on AIR particle technology (1012) (Alkermes, Cambridge, MA) (including time exposure and time-action profiles, PK and GD dose-response relationships, dose reproducibility, relative bioavailability, and relative biopotency compared with subcutaneous [SC] insulin lispro).
Twenty-two healthy, nonsmoking, male (10) or female (12) subjects with normal pulmonary function (at least 75% of predicted forced expiratory volume [FEV1] and forced vital capacity [FVC]) participated in the study. The age of the subjects was (means ± SD) 29.6 ± 6.9 years, and BMI was 23.2 ± 2.3 kg/m2. Subjects were ineligible if they had a history of asthma or a recent upper respiratory infection or if they had a medical history of diabetes, impaired glucose tolerance, allergy to insulin, or a fasting blood glucose >5.6 mmol/l. Pregnant women, nursing mothers, and subjects with serious medical conditions were also excluded. The local ethics committee approved the protocol. This phase I clinical trial was conducted according to the principles outlined in the Declaration of Helsinki and the International Conference on Harmonization Guideline to Good Clinical Practice. All subjects were given a full explanation of study procedures at the screening visit, and a signed informed consent was obtained for every subject.
This open-label, randomized, seven-period, incomplete block, cross-over, euglycemic glucose clamp study was conducted at one center (Profil Institut für Stoffwechselforschung, Neuss, Germany). Each subject received up to four single doses of human insulin inhalation powder (HIIP) (Eli Lilly and Company, Indianapolis, IN) (2.6, 3.6, 5.2, and 7.8 mg) and three single doses of SC lispro (Humalog; Eli Lilly and Company) supplied in 10-ml vials (100 units/ml; 6, 12, or 18 units),
There was a total of nine visits, including an initial screening visit and a final visit for a medical examination. At each visit in which a glucose clamp procedure was performed (visits 28), insulin was administered by inhalation or SC lispro injection
System description
Safety measurements Routine physical examinations and electrocardiograms were performed at screening and at visit 9 (or early termination from the study). Flow-volume spirometry (FEV1 and FVC) was performed at screening and at visit 9 to assess safety. For visits that included HIIP dosing, FEV1 and FVC were measured using a portable spirometer within 90 min before dosing and within 60 min after the end of the glucose clamp procedure.
PK analyses
Noncompartmental PK parameters, computed using WinNonlin (Professional edition, version 3.1; Pharsight, Cary, NC), included the maximum serum IRI concentration (Cmax), the time of maximum serum IRI concentration (tmax), and the area under the serum IRI concentration-versus-time curve from time zero until the serum IRI concentrations returned to the predose baseline value [AUC(0-t')]. An assessment of relative bioavailability (F) for HIIP compared with SC lispro was conducted based on AUC(0-t') according to equation 1:
GD analyses
A LOESS smoothing function was fitted to the glucose infusion rate (GIR) data by means of S-plus (version 2000). The maximum GIR (Rmax) and the time of maximum GIR (tRmax) were identified from the individual LOESS-fitted data. Other parameters, such as the times of 50% of maximum GIR before and after Rmax (early and late t50%), were also calculated based on the individual LOESS-fitted data. The total amount of glucose infused from time 0 to 10 h (Gtot) and the time of the first change in the GIR (tonset) were calculated from the raw GIR data. An additional LOESS fit was performed, where all GIR data from all subjects were fitted simultaneously in order to obtain predicted values per dose group. The relative biopotency (F') of HIIP compared with SC insulin lispro was calculated based on Gtot, according to equation 2:
Subject disposition Twenty of 22 subjects who entered the study proceeded to the first euglycemic clamp visit and received a study drug on at least one occasion. Eighteen subjects completed all study visits. None of the subjects discontinued due to an adverse event. Safety data from all 22 subjects were included in the safety analyses. Subjects who completed at least one glucose clamp procedure were included in the GD analyses. Those who completed one glucose clamp and had measurable IRI concentrations were included in the PK analyses. All available PK and GD data were included in the statistical analyses.
PK and GD results
For doses of HIIP comparable with SC lispro (2.6 mg to 6 units, 5.2 mg to 12 units, and 7.8 mg to 18 units, respectively), mean AUC(0-t') values were similar, while mean Cmax values appeared to be lower for HIIP. Thus, even though the insulin concentration versus time profile appeared to be prolonged for HIIP compared with SC lispro, the total insulin exposure was comparable for corresponding doses. Both the PK and GD profiles were flatter for HIIP than for SC lispro (Fig. 2AD), and at doses that provided similar overall exposure, total GD effects were also comparable (Table 1).
Based on AUC(0-t'), intersubject variability appeared to be larger for HIIP (42%) than for SC lispro (15%), while intrasubject variability was comparable between both (30%). Based on Gtot, intersubject variability was comparable between HIIP and SC lispro (27%), and intrasubject variability was comparable between both as well (28%). The predicted doses of HIIP that would be interchangeable with 6, 12, and 18 units of SC lispro were in excellent agreement with inhalation of the 2.6-, 5.2-, or 7.8-mg doses of HIIP (Table 1). The overall mean relative bioavailability and relative biopotency of HIIP compared with SC lispro across all doses tested were
Safety
This open-label, cross-over study in healthy subjects showed that inhalation of the HIIP formulation was safe and produced a similar initial rate of absorption, an extended insulin exposure, and a prolonged duration of effect when compared with SC lispro PK and GD profiles. Although Cmax values appeared to be lower with HIIP, the overall exposure and metabolic effect at similar doses was comparable between HIIP and SC lispro, as evidenced by both the PK and GD profiles being flatter for HIIP. This observation of comparable overall exposure and metabolic effect, coupled with the comparable intrasubject variability estimates for HIIP and SC lispro, suggests that patients may be able to transition between inhaled and SC lispro treatment with predictable results. In a clinical setting, predictable dose equivalence is important for successfully switching patients between different insulin formulations and routes of administration. This is the first study investigating dose equivalence of inhaled insulin versus an SC injected rapid-acting insulin analog like insulin lispro. With this study, we were able to demonstrate that the predicted doses were in good agreement with the actual HIIP doses used in the study, as confirmed by the narrow 95% CI observed for the predicted doses. The safety and tolerability of all HIIP doses was assessed as excellent, as no pulmonary-related adverse events were reported. This aligns with other studies using different insulin delivery systems in healthy subjects (1517) and patients with type 1 (18,19) and type 2 (2022) diabetes, during which pulmonary function testing was performed using spirometry. However, when measuring carbon monoxide lung diffusing capacity (DLco) small decreases were noted following inhalation of dry-powder insulin in several phase 2 and 3 studies of Exubera (18,22,23). The decreases in DLco occur quickly, are not progressive, and have not been associated with any clinical manifestations to date (18,22,23). As the current study focused on dose response and dose equivalence of HIIP in comparison to SC insulin lispro, DLco was not measured, which represents a limitation of the study. The most common respiratory adverse event in studies of inhaled Exubera is mild-to-moderate cough following inhalation of dry-powder insulin (18,22,23). The incidence of cough decreases over time and has not been associated with declines in lung function (18). It is remarkable that in the current study not a single episode of cough was registered, suggesting an excellent tolerability of the inhaled insulin when formulated by the AIR particle technology. This result, however, needs to be confirmed in much larger phase 3 trials. The administration of HIIP by means of a simple, handheld, breath-actuated inhaler in healthy subjects in this glucose-clamp study exhibited a slightly more rapid initial absorption of insulin compared with SC lispro coupled with a longer duration of metabolic activity than seen with SC lispro. These findings agree with other studies (24,25) comparing inhaled insulin with SC insulin lispro. In addition, the intrasubject variability for overall insulin exposure and GD effect was comparable with SC lispro. This finding also agrees with previous studies (21,26,27) investigating a number of different technologies for the delivery of inhaled insulin. One inhaled insulin system that demonstrates a different PK and GD profile is that of Technosphere (MannKind, Valencia, CA). This formulation exhibits a very rapid onset and very short (3 h) duration of insulin exposure and action when compared with regular SC insulin (16,28,29). Taken together, these results support the potential utility of inhaled insulin as an alternative to insulin injections. Because the fear of injections is a frequent cause for delaying appropriate care in patients with type 2 diabetes, inhaled insulin may provide a treatment that delivers effective doses of insulin in a less threatening, more satisfying manner, potentially resulting in improved patient compliance and better outcomes.
This study was funded by Eli Lilly and Company in collaboration with Alkermes. The authors acknowledge Drs. Bernard Silverman and Jen Schmitke from Alkermes for their collaboration on this project. Appreciation is also expressed to Kathryn Gilmore for preparation of the manuscript and to Peggy Campbell and Todd Cravens for editorial assistance. Parts of this study have been presented in abstract form at the 65th annual meeting of the American Diabetes Association, San Diego, California, 10-14 June 2005 [Rave K, Nosek L, de la Penña A, Segar M, Ernest C 2nd, Heinemann L, Batycky R, Muchmore D: Dose response and dose equivalency of human insulin inhalation powder (HIIP) using the Lilly/Alkermes Inhaled Insulin System compared to subcutaneous (SC) insulin lispro (Abstract). Diabetes 54 (Suppl. 1):A89, 2005].
A table elsewhere in this issue shows conventional and Système International (SI) units and conversion factors for many substances. Received for publication March 31, 2005. Accepted for publication July 11, 2005.
This article has been cited by other articles:
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||