Diabetes Care 31:971-973, 2008 DOI: 10.2337/dc07-1588 © 2008 by the American Diabetes Association
Serial Measurements of Cystatin C Are More Accurate Than Creatinine-Based Methods in Detecting Declining Renal Function in Type 1 Diabetes
1 Endocrine Centre, Austin Health, University of Melbourne, Melbourne, Australia Corresponding author: Dr. Erosha Premaratne, Endocrine Centre, Austin Health, Studley Road, Heidelberg, Victoria 3084, Australia. E-mail: erosha{at}aanet.com.au
OBJECTIVE—Cystatin C–and creatinine-based methods were compared with 99m-technetium-diethylene-triamine-penta-acetic acid (99mTc-DTPA) plasma clearance (isotopic glomerular filtration rate [iGFR]) for detecting declining renal function.
RESEARCH DESIGN AND METHODS—Glomerular filtration rate (GFR) was monitored over a mean of 10.1 years in 85 subjects with type 1 diabetes (with an average of 5.6 measurements per individual). Baseline mean ± SD iGFR of the cohort was 106.1 ± 2.6 ml/min per 1.73 m2. The rates of decline in GFR (
RESULTS—In 19 of 85 subjects with declining renal function (i.e., CONCLUSIONS—Cystatin C was more accurate in detecting decline in renal function than creatinine-based methods in this population of subjects with type 1 diabetes and a normal mean baseline GFR.
Abbreviations: GFR, glomerular filtration rate iGFR, isotopic GFR MDRD, Modification of Diet in Renal Disease 99mTc-DTPA, 99m-technetium-diethylene-triamine-penta-acetic acid
Monitoring trends in renal function via glomerular filtration rate (GFR) is of critical importance in managing patients with diabetes. Gold-standard methods for determining GFR employing plasma clearance techniques are cumbersome and not adaptable to routine clinical practice. Limitations of serum creatinine–and creatinine-based equations for estimation of GFR are well known (1,2). Cystatin C concentration has been proposed as an endogenous marker of GFR superior to creatinine (3,4). We compared serum cystatin C, creatinine, Cockcroft-Gault formula, and the Modification of Diet in Renal Disease (MDRD)-4 and -6–variable equations with direct measurement of renal function employing 99m-technetium-diethylene-triamine-penta-acetic acid (99mTc-DTPA) plasma clearance (isotopic GFR [iGFR]) in longitudinal monitoring of GFR in 85 subjects with type 1 diabetes with baseline GFR values predominantly in the normal range. In particular, the accuracy of the above methods for identifying subjects with progressively declining renal function was examined.
A search of our database located 85 subjects with type 1 diabetes attending the Diabetes Clinics at Austin Health (a tertiary referral center) in Melbourne, Australia, in whom at least two iGFR measurements had been performed 3 or more years apart between 1987 and 2004. Subjects with nondiabetic renal disease were excluded. All subjects were Caucasian, except for one who was of Chinese ethnicity. GFR measurements utilizing 99mTc-DTPA plasma clearance (iGFR) were routinely performed (5,6) on all clinic attendees two to three times yearly, irrespective of renal function or albuminuria status. At baseline, mean ± SEM age of the 85 subjects (n = 85, 49 male) was 38.4 ± 1.3 years (range 14–72) and the mean ± SEM disease duration was 13.7 ± 1.1 years (range 0.2–48.6). On average, 5.6 iGFR measurements had been performed on each individual (range 2–11). The initial mean ± SEM iGFR was 106.1 ± 2.6 ml/min per 1.73 m2, which declined to 90.4 ± 3.4 ml/min per 1.73 m2 after 10.1 ± 0.3 years (range 3.0–15.7) of follow-up. The initial iGFR was >120 in 27%, 90–120 in 54%, and <90 ml/min per 1.73 m2 in 19% of the subjects. From these 85 subjects, those with a rate of decline in iGFR >3.3 ml/min per 1.73 m2 per year were defined as having a declining renal function ("decliners," n = 19) based on longitudinal data from the Baltimore Longitudinal Study of Aging (7). Serum for creatinine and cystatin C was collected on the same morning as the corresponding iGFR measurement. Creatinine assays were determined by the Jaffe alkaline picrate method in the same laboratory, using a Parallel American Monitor (1987–1993), a Hitachi 747 instrument (1994–1997), or a Hitachi 917 automatic analyzer (1998–2004). There was no difference between GFR estimates obtained with the three creatinine methods and the corresponding iGFR measurements when analyzed by the Bland-Altman method. The latter assay produced creatinine values that fell within ±15% of the reference MDRD method, an accuracy that has been endorsed by the Australian Creatinine Consensus Working Group on automatic reporting of estimated GFR (8). The intra- and interassay coefficients of variation (CVs) for serum creatinine were 2.3 and 6.7%, respectively, using the Hitachi 917 analyzer. Cystatin C was measured from stored serum samples in a single batch in 2004 using an automated particle-enhancing immunonephelometric assay on a BN II instrument (Dade Behring, Marburg, Germany). The intra- and interassay CVs for cystatin C were 2.58 and 3.95%, respectively, at a concentration of 1.54 mg/l.
The following techniques were used to estimate GFR: creatinine was transformed to a GFR value (Cr-GFR) using the equation 104/serum creatinine (µmol/l). Cystatin C was transformed to a GFR equivalent using the equation Cys-GFR = (86.7/cystatin C concentration) – 4.2 (3). Standard formulas were used to derive GFR from Cockcroft-Gault formula (CG-GFR) (9) and MDRD equations (1). For each individual, the trends of GFR (
The baseline and final iGFR in the group of decliners (n = 19) was mean ± SEM 105.1 ± 7 and 51.6 ± 7 ml/min per 1.73 m2, respectively, compared with 106.3 ± 3 and 101.5 ± 3 ml/min per 1.73 m2 in the nondecliners. Decliners had a greater baseline A1C than nondecliners (P < 0.05). The median baseline and final albumin excretion rates were18 and 150 µg/min, respectively, in decliners and 9 and 10 µg/min, respectively, in nondecliners. Thus, both baseline and final albumin excretion rate was higher in decliners than nondecliners (P < 0.02).
The mean
This study demonstrates that estimates of renal function derived from serum cystatin C accurately portray long-term changes in GFR when compared with serial iGFR measurements in a cohort of subjects with type 1 diabetes with declining renal function. In contrast, creatinine-based estimates such as the Cockcroft-Gault formula and MDRD-4 and -6 variable equations and 1/creatinine significantly underestimated the decline in iGFR in this population. Thus serial measurements of serum cystatin C may facilitate early identification of patients at risk of developing renal failure. Cystatin C has the potential to be employed more widely for monitoring of GFR, given its advantages of availability of a simple and accurate automated assay and the ability to directly use the reciprocal of cystatin C level as a GFR equivalent.
This study was supported by grants from the Pfizer Cardiovascular Lipid Grant Scheme and the Austin Hospital Medical Research Foundation and by Melbourne University Postgraduate Research grants. This study was presented in abstract form at the 67th annual meeting of the American Diabetes Association, Chicago, Illinois, 22–26 June 2007.
Published ahead of print at http://care.diabetesjournals.org on 4 March 2008. DOI: 10.2337/dc07-1588. The costs of publication of this article were defrayed in part by the payment of page charges. This article must therefore be hereby marked "advertisement" in accordance with 18 U.S.C. Section 1734 solely to indicate this fact. Received for publication August 11, 2007. Accepted for publication January 28, 2008.
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||