DOI: 10.2337/dc07-0571
Comparison of accuracy measures of two screening tests for gestational diabetes mellitus
1 Obstetrics and Gynaecology, Academic Medical Centre, Amsterdam, The Netherlands Marsha.vanLeeuwen{at}amc.uva.nl ABSTRACT Objective: To compare the accuracy measures of the random glucose test and the 50 g glucose challenge test as screening tests for gestational diabetes mellitus. Research design and methods: In this prospective cohort study pregnant women without pre-existing diabetes mellitus in two perinatal centres in The Netherlands underwent a random glucose test and a 50 g glucose challenge test between 24 and 28 weeks of gestation. If one of the screening tests exceeded predefined threshold values, the 75 g oral glucose tolerance test (OGTT) was performed within one week. Furthermore the OGTT was performed in a random sample of women in whom both screening tests were normal. Gestational diabetes was considered present when the OGTT (reference test) exceeded predefined threshold values. Receiver operating characteristic analysis was used to evaluate the performance of the two screening tests. The results were corrected for verification bias. Results: We included 1301 women. The OGTT was performed in 322 women. After correction for verification bias, the random glucose test showed an area under the ROC curve (AUC) of 0.69 (95% CI 0.61 to 0.78) whereas the glucose challenge test had an AUC of 0.88 (95% CI 0.83 to 0.93). There was a significant difference in area under the curve of the two tests of 0.19 (95% CI 0.11 to 0.27) in favour of the 50 g glucose challenge test. Conclusions: In screening for gestational diabetes mellitus, the 50 g glucose challenge test is more useful than the random glucose test.
|
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||