The Plasma Glucose Response of Normal Fasting Subjects to Neutral Regular and NPH Biosynthetic Human and Purified Pork Insulins
- Lilly Laboratory for Clinical Research and the Department of Medicine, Indiana University School of Medicine Indianapolis, Indiana
- Address reprint requests to John A. Galloway, Lilly Clinic, Wishard Memorial Hospital, 1001 West 10th Street, Indianapolis, Indiana 46202.
Abstract
Using doses of 0.1 and 0.15 U/kg, the hypoglycemic activities of neutral regular and NPH biosynthetic human insulin (BHI) and purified pork insulin were compared in normal fasting subjects. Neutral regular insulin was administered by the intravenous and subcutaneous routes and NPH subcutaneously. Comparison of the plasma glucose curves disclosed no statistically significant differences between the maximum effects and the length of time to achieve the maximum effect. Moreover, a dose-response difference between 0.1 and 0.15 U/kg could not established. It is concluded that the hypoglycemic activities of neutral regular and NPH BHI and purified pork insulin are the same.
- Copyright © 1981 by the American Diabetes Association