OBJECTIVE—To evaluate corneal advanced glycation end product (AGE) fluorescence in patients with diabetes and in healthy control subjects.

RESEARCH DESIGN AND METHODS—Corneal autofluorescence was measured in 26 eyes of 26 patients with type 2 diabetes (mean age 57.0 years; mean disease duration 12.2 years; mean HbA1c 7.1%) and 13 eyes of 13 healthy age-matched control subjects (mean age 57.9 years). The patients with type 2 diabetes were divided into the following groups: patients without diabetic retinopathy (DR), patients without proliferative diabetic retinopathy (PDR), and patients with PDR. Corneal autofluorescence was measured by fluorophotometry with the wavelength that is characteristic of AGE fluorescence (excitation and emission 360–370 nm and 430–450 nm, respectively). We defined peak corneal autofluorescence levels as corneal AGE fluorescence values. We compared the corneal AGE fluorescence values in the four groups.

RESULTS—In the PDR group (11.9 ± 3.9 arbitrary units [mean ± SD]), the corneal AGE fluorescence values were significantly higher compared with the control subjects (6.9 ± 1.3 arbitrary units), the patients without DR (7.4 ± 2.1 arbitrary units), and the patients without PDR (6.9 ± 2.2 arbitrary units) (P < 0.05).

CONCLUSIONS—We found that corneal AGEs may increase in patients with diabetes and PDR compared with control subjects, patients without DR, and patients without PDR. In the patients with PDR, increased corneal AGEs may play a role in diabetic keratopathy.

The nonenzymatic glycation of proteins in a process known as the Maillard reaction eventually causes the formation of advanced glycation end products (AGEs) (1). AGEs have been implicated as causal factors in the complications of diabetes (2), including diabetic retinopathy (DR) (36), and have specific fluorescence characteristics (1,7,8).

We previously showed that corneal autofluorescence values measured using a commercial fluorophotometer significantly increased in patients with proliferative diabetic retinopathy (PDR) (9). Moreover, we reported that lens autofluorescence values using our fluorophotometer were significantly correlated with AGE levels in extracted lenses in diabetic animal models (10).

In the present study, we measured corneal autofluorescence using our fluorophotometer, the wavelength of which was characteristic of AGE fluorescence, and evaluated corneal AGEs in patients with type 2 diabetes and in healthy control subjects.

Corneal autofluorescence was measured in 26 eyes of 26 patients with type 2 diabetes and 13 eyes of 13 healthy age-matched control subjects. The patients with type 2 diabetes were divided into three groups: patients without DR, patients without PDR, and patients with PDR (Table 1). Eyes that had undergone surgery were excluded from this study. The study protocol was reviewed by the ethics committee of our institution. All procedures adhered to the tenets of the Declaration of Helsinki.

Corneal autofluorescence was measured by scanning with a lens measurement system (SpectRx) (11) that had been adjusted for corneal measurement. The system has a xenon lamp as an excitation source and a fluorescence detector. The noninvasive corneal autofluorescence measurements were performed at various distances along the optical axis of the cornea with the assistance of a pupil-tracking system. The pupil-tracking system, an automatic alignment system, was incorporated into the lens measurement system and works as follows. An infrared charged-coupled–device camera images the iris and the pupil, and the image is digitized. The position data derived from the digitized charged-coupled–device image are fed into a two-axis servomotor positioning system to maintain the x and y positions of the sample volume to within ±100 μm of the programmed “lock” position (11). The sample volume in the optics of the lens measurement system was ∼300 μm long, 600 μm high, and 80 μm wide. We used color filters at wavelengths of 360–370 nm for excitation and 430–450 nm for emission, because 360–370 and 430–450 nm (excitation and emission, respectively) were reported to be characteristic of AGE fluorescence (i.e., crossline, etc.) in the tissue (1,7,8). We reported that there was a significant positive correlation between lens autofluorescence values and the AGE levels in the same extracted lenses in diabetic hamsters (10). We used the peak corneal autofluorescence level as the corneal autofluorescence value. The corneal autofluorescence values measured by our fluorophotometry are defined as corneal AGE fluorescence. The corneal AGE fluorescence values are expressed as arbitrary units.

We compared the corneal AGE fluorescence values in the four groups of patients and examined the relationship between these values and age, duration of disease, and HbA1c levels in the patients with type 2 diabetes.

Data analysis

The results were expressed as means ± SD. The distribution of corneal AGE fluorescence values in these four groups was compared using a one-way of analysis variance and Scheffe’s test. A P value of 0.05 or lower was considered significant. The Pearson correlation coefficient (r) was calculated to determine whether there were significant relationships between variables.

The results of the corneal AGE fluorescence values in the four groups of patients are shown in Fig. 1. The corneal AGE fluorescence values in the control subjects, the patients without DR, the patients without PDR, and the patients with PDR were 6.9 ± 1.3, 7.4 ± 2.1, 6.9 ± 2.2, and 11.9 ± 3.9 arbitrary units (mean ± SD), respectively. A significant difference was noted in the corneal AGE fluorescence values between the four groups (analysis of variance, P = 0.0001); corneal AGE fluorescence values were markedly higher in the patients with PDR than in the control subjects, the patients without DR, or the patients without PDR (Scheffe’s test; P = 0.0006, P = 0.0053, and P = 0.0078, respectively). In the patients with type 2 diabetes, no significant correlation was found between corneal AGE fluorescence values and age (r = 0.063), duration of disease (r = 0.21) (Fig. 2), or HbA1c level (r = 0.38) (Fig. 3).

In the present study, we measured corneal AGE fluorescence values using our fluorophotometry system, the wavelength of which was characteristic of AGE fluorescence (1,7,8). We previously reported that there was a correlation between lens autofluorescence values detected by our fluorophotometry system and AGE levels in the same lenses measured by an enzyme-linked immunosorbent assay in diabetic animals (10). The previous reported results showed a strong correlation between the value of lens autofluorescence measured with the 360- to 370-nm and 430- to 450-nm wavelengths (excitation and emission, respectively) and the AGE levels measured by enzyme-linked immunosorbent assay in the same extracted lenses (10). It also has been reported that oxidized LDLs (oxLDLs), which are believed to increase in patients with diabetes, generate fluorescent products with emission at 430 nm when excitation is performed at 360 nm (1214). That wavelength is characteristic of oxLDL fluorescence and similar to that of AGE fluorescence. However, there is much less autofluorescence of oxLDL than of AGEs (14). Thus, it is possible that corneal autofluorescence induced by these wavelengths as AGE fluorescence measured by our fluorophotometry might mainly reflect corneal AGE fluorescence.

Sady et al. (15), using a two-step high-performance liquid chromatography assay, reported the presence of pentosidine in the cornea. They also reported that those pentosidine levels correlated with the collagen-bound fluorescence and pentosidine levels and that collagen-bound fluorescence was higher in human diabetic corneas than in control corneas. Those authors suggested that AGEs in the cornea increase in patients with diabetes. Kaji et al. (16) reported that N-(carboxymethyl) lysine (CML) immunoreactivity was observed at the site of the epithelial basement membrane in the corneas of patients with diabetes. AGEs, which are produced by the nonenzymatic reaction of glucose and other aldoses with protein via the Maillard reaction and have specific fluorescence characteristics, seem to accumulate in the corneas of patients with diabetes. In the present study, the corneal AGE fluorescence value in the group of patients with PDR was significantly higher than that in the control subjects, the patients without DR, and the patients without PDR. These results indicate that corneal AGEs increase in patients with PDR.

Using our fluorophotometry, corneal AGE fluorescence could not be broken into separate signals from the corneal epithelium, stroma, and endothelium. The pentosidine concentration in human corneal collagen is increased in patients with diabetes (15). These results suggest that pentosidine, which is an AGE, can cause increased fluorescence in the corneal stroma of patients with diabetes. However, CML, which is another AGE, was observed at the site of the epithelial basement membrane in corneas of patients with diabetes (16). The distribution of AGEs in the corneas of patients with diabetes is still unclear.

In the present study, there was no correlation between HbA1c levels or duration of disease and corneal AGE fluorescence values in the patients with type 2 diabetes. However, corneal AGE fluorescence values increased only in the patients with PDR. The vitreous concentrations of AGEs and vascular endothelial growth factor (VEGF) were both elevated in the patients with PDR (5,17,18). VEGF plays a role in breakdown of the blood-retinal barrier (BRB) (1921). Increased values of AGEs in the vitreous in patients with PDR seem to be related to breakdown of the BRB. Furthermore, some authors reported that permeability of the blood-aqueous barrier (BAB) increased in patients with PDR (22,23). We speculated that increased corneal AGEs in patients with PDR may be caused by an increase of AGEs in the aqueous humor and vitreous resulting from breakdown of the BRB and/or BAB.

Diabetic corneal epitheliopathy has been recognized clinically, especially after vitrectomy (24). Structural changes in the endothelium have been reported in patients with diabetes (25,26). In corneas of patients with diabetes, decreased sensation, neurotrophic ulceration, delayed wound healing, recurrent erosions, and epithelial edema have been found clinically. Histologically, thickening and multilayering of the epithelial basement membrane and morphologic changes of the corneal epithelial cells have been reported (27). These changes are assumed to be due to intracellular edema, which may result from activation of the sorbitol pathway. The aldose reductase inhibitor has been reported to be effective in treating corneal epithelial defects (28). However, the pathogenic mechanisms underlying those abnormalities are still unclear. In vitro, nonenzymatic glycation of laminin-attenuated adhesion and spreading of corneal epithelial cells and the presence of aminoguanidine, an inhibitor of AGE formation in the incubation mixture during glycation, inhibited CML formation and promoted adhesion and spreading of corneal epithelial cells (16). We hypothesized that one of the corneal complications of diabetes, especially in patients with PDR, could be related to the accumulation of AGEs in the cornea. We believe that this should be considered in the future.

In conclusion, these results demonstrate that corneal AGEs may increase in patients with PDR compared with control subjects, patients without DR, and patients without PDR. In patients with PDR, increased corneal AGEs may play a role in diabetic keratopathy.

Figure 1 —

Corneal AGE fluorescence values in healthy control subjects, patients without DR (non-DR), patients without PDR (non-PDR), and patients with PDR (PDR) (Scheffe’s test; *** P = 0.0006, **P = 0.0053, *P = 0.0078).

Figure 1 —

Corneal AGE fluorescence values in healthy control subjects, patients without DR (non-DR), patients without PDR (non-PDR), and patients with PDR (PDR) (Scheffe’s test; *** P = 0.0006, **P = 0.0053, *P = 0.0078).

Close modal
Figure 2 —

Relationship between duration of disease and corneal AGE fluorescence values in patients with type 2 diabetes. A statistically significant correlation was not found (r = 0.21, P = 0.3105).

Figure 2 —

Relationship between duration of disease and corneal AGE fluorescence values in patients with type 2 diabetes. A statistically significant correlation was not found (r = 0.21, P = 0.3105).

Close modal
Figure 3 —

Relationship between HbA1c levels (%) and corneal AGE fluorescence values in patients with type 2 diabetes. A statistically significant correlation was not found (r = 0.38, P = 0.0893).

Figure 3 —

Relationship between HbA1c levels (%) and corneal AGE fluorescence values in patients with type 2 diabetes. A statistically significant correlation was not found (r = 0.38, P = 0.0893).

Close modal
Table 1 —

Demographic data from patients with type 2 diabetes and healthy control subjects

Number of individualsAge (years)Duration of diabetes (years)HbA1c (%)
Patients with diabetes 26 57.0 ± 9.2 12.2 ± 6.6 7.1 ± 1.2 
 NO DR group 59.9 ± 5.6 11.2 ± 7.6 6.9 ± 0.8 
 NO PDR group 59.5 ± 13.1 12.8 ± 7.6 8.1 ± 1.3 
 PDR group 12 53.9 ± 8.6 12.8 ± 5.7 6.9 ± 1.2 
Healthy control subjects 13 57.9 ± 16.8 — — 
Number of individualsAge (years)Duration of diabetes (years)HbA1c (%)
Patients with diabetes 26 57.0 ± 9.2 12.2 ± 6.6 7.1 ± 1.2 
 NO DR group 59.9 ± 5.6 11.2 ± 7.6 6.9 ± 0.8 
 NO PDR group 59.5 ± 13.1 12.8 ± 7.6 8.1 ± 1.3 
 PDR group 12 53.9 ± 8.6 12.8 ± 5.7 6.9 ± 1.2 
Healthy control subjects 13 57.9 ± 16.8 — — 

Data are means ± SD.

We thank N. Moriyama and M. Nakagawa, Teijin Limited, for technical assistance in measuring corneal autofluorescence.

1
Monnier VM, Cerami A: Nonenzymatic browning in vivo: possible process for aging of long-lived proteins.
Science
211
:
491
–493,
1981
2
Mitsuhashi T, Nakayama H, Itoh T, Kuwajima S, Aoki S, Atsumi T, Koike T: Immunochemical detection of advanced glycation end products in renal cortex from STZ-induced diabetic rats.
Diabetes
42
:
826
–832,
1993
3
Hammes HP, Brownlee M, Edelstein D, Saleck M, Martin S, Federlin K: Aminoguanidine inhibits the development of accelerated diabetic retinopathy in the spontaneous hypertensive rat.
Diabetologia
37
:
32
–35,
1994
4
Murata T, Nagai R, Ishibashi T, Inomata H, Ikeda K, Horiuchi S: The relationship between accumulation of advanced glycation end products and expression of vascular endothelial growth factor in human diabetic retinas.
Diabetologia
40
:
764
–769,
1997
5
Stitt AW, Moore JE, Sharkey JA, Murphy G, Simpson DAC, Bucala R, Vlassara H: Advanced glycation end products in vitreous: structural and functional implications for diabetic vitropathy.
Invest Ophthalmol Vis Sci
39
:
2517
–2523,
1998
6
Hammes HP, Brownlee M, Lin J, Schleicher E, Bretzel RG: Diabetic retinopathy risk correlates with intracellular concentrations of the glycoxidation product N-(carboxymethyl) lysine independently of glycohaemoglobin concentrations.
Diabetologia
42
:
603
–607,
1999
7
Liang JN, Rossi MT: In vitro-enzymatic glycation and formation of browning products in the bovine lens α-crystallin.
Exp Eye Res
50
:
367
–371,
1990
8
Obayashi H, Nakano K, Shigeta H, Yamaguchi M, Yoshimori K, Fukui M, Fujii M, Kitagawa Y, Nakamura N, Nakanura K, Nakazawa Y, Ienaga K, Ohta M, Nishimura M, Fukui I, Kondo M: Formation of crossline as a fluorescent advanced glycation end product in vitro and in vivo.
Biochem Biophys Res Commun
226
:
37
–41,
1996
9
Mori F, Ishiko S, Abiko T, Kitaya N, Kato Y, Kanno H, Yoshida A: Changes in corneal and lens autofluorescence and blood glucose levels in diabetics: parameters of blood glucose control.
Curr Eye Res
16
:
534
–538,
1997
10
Abiko T, Abiko A, Ishiko S, Takeda M, Horiuchi S, Yoshida A: Relationship between autofluorescence and advanced glycation end products in diabetic lenses.
Exp Eye Res
68
:
361
–366,
1999
11
Yu NT, Krantz BS, Eppstein JA, Ignotz KD, Samuels MA, Long JR, Price JF: Development of a noninvasive diabetes screening device using the ratio of fluorescence to Rayleigh scattered light.
J Biomed Opt
1
:
280
–288,
1996
12
Makita Z, Yanagisawa K, Kuwajima S, Bucala R, Vlassara H, Koike T: The role of advanced glycation end products in the pathogenesis of atherosclerosis.
Nephrol Dial Transplant
11
:
31
–33,
1996
13
Lopes-Virella MF, Koskinen S, Mironova M, Horne D, Klien R, Chassereau C, Enockson C, Virella G: The preparation of copper-oxidized LDL for the measurement of oxidized LDL antibodies by EIA.
Atherosclerosis
152
:
107
–115,
2000
14
Menzel EJ, Sobal G, Staudinger A: The role of oxidative stress in the long-term glycation of LDL.
Biofactors
6
:
111
–124,
1997
15
Sady C, Khosrof S, Nagaraj R: Advanced Maillard reaction and crosslinking of corneal collagen in diabetes.
Biochem Biophys Res Commun
214
:
793
–797,
1995
16
Kaji Y, Usui T, Oshika T, Matsubara M, Yamashita H, Araie M, Murata T, Ishibashi T, Nagai R, Horiuchi S, Amano S: Advanced glycation end products in diabetic corneas.
Invest Ophthalmol Vis Sci
41
:
362
–368,
2000
17
Hirata C, Nakano K, Nakamura N, Kitagawa Y, Shigeta H, Hasegawa G, Ogata M, Ikeda T, Sawa H, Nakamura K, Ienaga K, Obayashi H, Kondo M: Advanced glycation end products induce expression of vascular endothelial growth factor by retinal Muller cells.
Biochem Biophys Res Commun
236
:
712
–715,
1997
18
Aiello LP, Avery RL, Arrigg PG, Keyt B, Aiello LM, Jampel HD, Shah ST, Pasquale LR, Thieme H, Iwamoto MA, Park JE, Nguyen HV, Ferrara N, King GL: Vascular endothelial growth factor in ocular fluids of patients with diabetic retinopathy and other retinal disorders.
N Engl J Med
331
:
1480
–1487,
1994
19
Murata T, Ishibashi T, Khalil A, Hata Y, Yoshikawa H, Inomata H: Vascular endothelial growth factor plays a role in hyperpermeability of diabetic retinal vessels.
Ophthalmic Res
27
:
48
–52,
1995
20
Antonetti DA, Barber AJ, Khin S, Lieth E, Tarbell JM, Gardner TW: Vascular permeability in experimental diabetes is associated with reduced endothelial occludin content: vascular endothelial growth factor decreases occludin in retinal endothelial cells.
Diabetes
47
:
1953
–1959,
1998
21
Bursell SE, Delori FC, Yoshida A, Parker JS, Collas GD, McMeel W: Vitreous fluorophotometric evaluation of diabetics.
Invest Ophthalmol Vis Sci
25
:
703
–710,
1984
22
Moriarty AP, Spalton DJ, Moriarty BJ, Shilling JS, Ffytche TJ, Bulsala M: Studies of the blood aqueous barrier in diabetes mellitus.
Am J Ophthalmol
117
:
768
–771,
1994
23
Yoshida A, Ishiko S, Kojima M, Ogasawara H: Permeability of the blood-ocular barrier in adolescent and adult diabetic patients.
Br J Ophthalmol
77
:
158
–161,
1993
24
Perry HD, Foulks GN, Thoft RA, Tolentino FI: Corneal complications after closed vitrectomy through the pars plana.
Arch Ophthalmol
96
:
1401
–1403,
1978
25
Keoleian GM, Pach JM, Hodge DO, Trocme SD, Bourne WM: Structural and functional studies of the corneal endothelium in diabetes mellitus.
Am J Ophthalmol
113
:
64
–70,
1992
26
Schultz RO, Matsuda M, Yee RW, Edelhauser HF, Schultz KJ: Corneal endothelial changes in type I and type II diabetes mellitus.
Am J Ophthalmol
98
:
401
–410,
1984
27
Friend J, Ishii Y, Thoft RA: Corneal epithelial changes in diabetic rats.
Ophthalmic Res
14
:
269
–278,
1982
28
Ohashi Y, Matsuda M, Hosotani H, Tano Y, Ishimoto I, Fukuda M, Manabe R: Aldose reductase inhibitor (CT-112) eye drops for diabetic corneal epitheliopathy.
Am J Ophthalmol
105
:
233
–238,
1988

Address correspondence and reprint requests to Fumihiko Mori, MD, PhD, Department of Ophthalmology, Asahikawa Medical College, 2-1-1 Midorigaoka-higashi, Asahikawa, Hokkaido 078-8510, Japan. E-mail: morinao@d5.dion.ne.jp.

Received for publication 29 June 2000 and accepted in revised form 10 November 2000.

A table elsewhere in this issue shows conventional and Système International (SI) units and conversion factors for many substances.