Pulmonary-delivered insulin is again a reality (1). The failure of the first inhaled insulin in 2007 showed that being radically different from what health care providers are used to, even when injections are avoided, can be problematic. The current product Technosphere inhaled insulin has addressed many of the prior concerns—a more convenient delivery device that is dosed in insulin units. Also, fear of lung toxicity or tumor development has been lessened somewhat by in vitro cytotoxic (2) and in vivo clearance (3) studies, plus a 2-year clinical trial showed no differences in pulmonary imaging or function in Technosphere-treated and untreated subjects with diabetes (4). In addition, aerosolized medicines that have effective absorption into the bloodstream are well established (5), with numerous agents having been tried including glucagon-like peptide 1 (6).

A highly touted feature of pulmonary-delivered insulin is its rapid absorption—peak absorption by 10–15 min and fully cleared by 2–3 h versus a peak of 45–60 min and clearance of 5–6 h for injected analog prandial insulins (1,7) (Fig. 1). The potential importance of an ultrafast “on response” relates to the phasic nature of endogenously secreted insulin. An intravenous glucose infusion in humans without diabetes elicits a distinct first phase of insulin secretion over the first 10 min that is followed by a short lull and then a sustained second phase for the duration of the hyperglycemia. Actually, the diverse nutrient makeup of meals and their oral delivery initiate a more broad-based insulin response that does not separate into distinct phases. Still, the early insulin that is secreted into the portal vein serves a key role to rapidly turn off hepatic glucose production (8) and likely contributes to the fall in glucagon and controlled rise and fall in circulating free fatty acids that collectively characterize normal prandial metabolism. A defining feature of type 2 diabetes is a near-total absence of the early insulin response, while the later phase is present and often exaggerated because of the hyperglycemia, i.e., mealtime insulin is delayed (9,10). Restoring early insulin with a short-term insulin infusion in type 2 diabetes markedly improved prandial glycemia and lipemia (11). Hence, a reasonable conclusion is the earliest secreted insulin is a necessary element of the normal mealtime insulin response, and consequently optimal exogenous prandial insulin needs a rapid “on response.” And Technosphere insulin is the best we have. However, a question that needs to be answered is whether that difference provides any meaningful clinical advantage over the injected prandial insulins.

Figure 1

Pharmacokinetic profiles (mean ± SE) of inhaled Technosphere insulin and subcutaneously injected rapid-acting insulin analog insulin presented by Cassidy et al. at the 69th Scientific Sessions of the American Diabetes Association, New Orleans, LA, 5–9 June 2009. Reproduced from Boss et al. (7).

Figure 1

Pharmacokinetic profiles (mean ± SE) of inhaled Technosphere insulin and subcutaneously injected rapid-acting insulin analog insulin presented by Cassidy et al. at the 69th Scientific Sessions of the American Diabetes Association, New Orleans, LA, 5–9 June 2009. Reproduced from Boss et al. (7).

Close modal

Two studies in this issue of Diabetes Care provided insight into how this insulin performs. Bode et al. (12) performed a 24-week noninferiority open-label study of subjects with type 1 diabetes that received injected basal and aspart insulins (basal-bolus) or injected basal and inhaled Technosphere insulin at meals. The main finding was noninferiority with the attained A1C values falling within the agreed-upon study criteria of within 0.4%. The basal-bolus group fell from 7.9% after basal insulin optimization to 7.5% at the end of the study versus 7.9% to 7.7% in the inhaled insulin group. However, the percent of subjects attaining A1C ≤7% was superior in the injection group (31% vs. 18%), and the 7-point glucose profiles showed better control in the injected insulin group at all times except fasting. Otherwise, there were no major surprises or concerns over the use or safety of inhaled insulin.

Thus, for type 1 diabetes, the fact that inhaled insulin was not more effective than prandial injections and probably less effective (despite meeting the noninferiority criteria) seems predictable as the rapid insulin profile likely runs out too soon on the background of complete insulin deficiency. However, features of inhaled insulin raise novel possibilities that might allow for creative ways to take advantage of its unique action profile. Importantly, Bode et al. found the faster “off time” of inhaled insulin lowered the risk of hypoglycemia 2–5 h after a meal versus the injected prandial insulin. As such, second inhalations 90–120 min after meals, as discussed elsewhere (7), could be a powerful strategy for fine-tuning mealtime insulin coverage while minimizing the risk of hypoglycemia, especially if used with continuous glucose monitoring. A second intriguing possibility is using inhaled insulin together with injected prandial insulin to get an early insulin boost. Technosphere insulin added at the start of a meal with a closed-loop pump system has been shown to result in superior mealtime glycemic control (13,14).

The study by Rosenstock et al. (15) is a 24-week comparison in subjects with type 2 diabetes poorly controlled with oral antidiabetes agents of adding mealtime Technosphere inhaled insulin or a placebo inhalation (the Technosphere matrix fumaryl diketopiperazine) to their usual antidiabetes medications, which were mostly metformin or sulfonylurea and metformin. Thus, a notable aspect of this study is inhaled insulin without basal insulin—a true injection-free program. The main finding was as expected—a statistically superior lowering of A1C with the inhaled insulin from baseline 8.3% to 7.4% versus to 7.8% with the Technosphere placebo. There was also a modest doubling of nonserious hypoglycemia with the inhaled insulin, mostly in sulfonylurea-treated patients. These findings support a smaller, shorter study with a similar protocol (16).

Remembering that the principal prandial insulin secretory defect in type 2 diabetes is a delayed mealtime response (9,10), one might have hoped for an even lower A1C with the inhaled insulin. Studies with injected prandial insulin alone in type 2 diabetes have shown better A1C values, but with considerably more hypoglycemia (17,18). However, a striking finding in the study by Rosenstock et al. (15) is the 7-point glucose profile: inhaled insulin did a good job at controlling the postmeal values, although a caveat is that the testing was done 90 min after starting the meal, before the insulin effect is over. Failure to see a lower A1C value was shown to be because of no appreciable impact of the inhaled insulin on fasting blood glucose.

Thus, a key question is whether a combination of properly titrated inhaled insulin and injected basal insulin would produce a superior and safer approach than injected basal-bolus insulin in type 2 diabetes. This is reminiscent of how the combination insulin and glucagon-like peptide 1 receptor agonist story evolved—similar overall blood glucose control from different patterns of improvement when twice-daily exenatide (postprandial) and glargine insulin (fasting and premeal) were used individually (19) but amazing glycemic control when used together (20). So far there is insufficient evidence to know what to expect from the combination of Technosphere insulin and injected basal insulin. A 52-week study of glargine insulin and Technosphere inhaled insulin used together lowered A1C from 8.7% to 8.0% (21). In contrast, A1C values in a study of injected basal-bolus insulin fell from 8.1–8.3% to 6.5–6.7%, but with substantial weight gain and hypoglycemia (22).

In summary, the ultrafast profile of inhaled Technosphere insulin is novel and brings several possibilities. Of particular interest is intensive mealtime insulin coverage with less hypoglycemia through repeat doses or if used with injected prandial insulin. However, these possibilities are more speculative than proven. As such, inhaled insulin is still a convenience product rather than a proven advance in insulin therapy. However, it is at the forefront of several faster insulins that are in development (22,23). And the question remains—is faster better?

See accompanying articles, pp. 2200, 2204, 2211, 2217, 2226, 2234, 2237, 2241, 2250, 2258, 2266, and 2274.

Duality of Interest. No potential conflicts of interest relevant to this article were reported.

1.
Santos Cavaiola
T
,
Edelman
S
.
Inhaled insulin: a breath of fresh air? A review of inhaled insulin
.
Clin Ther
2014
;
36
:
1275
1289
[PubMed]
2.
Angelo
R
,
Rousseau
K
,
Grant
M
,
Leone-Bay
A
,
Richardson
P
.
Technosphere insulin: defining the role of Technosphere particles at the cellular level
.
J Diabetes Sci Technol
2009
;
3
:
545
554
[PubMed]
3.
Cassidy
JP
,
Amin
N
,
Marino
M
, et al
.
Insulin lung deposition and clearance following Technosphere insulin inhalation powder administration
.
Pharm Res
2011
;
28
:
2157
2164
[PubMed]
4.
Raskin
P
,
Heller
S
,
Honka
M
, et al
.
Pulmonary function over 2 years in diabetic patients treated with prandial inhaled Technosphere insulin or usual antidiabetes treatment: a randomized trial
.
Diabetes Obes Metab
2012
;
14
:
163
173
[PubMed]
5.
Scheuch
G
,
Kohlhaeufl
MJ
,
Brand
P
,
Siekmeier
R
.
Clinical perspectives on pulmonary systemic and macromolecular delivery
.
Adv Drug Deliv Rev
2006
;
58
:
996
1008
[PubMed]
6.
Siekmeier
R
,
Hofmann
T
,
Scheuch
G
,
Pokorski
M
.
Aerosolized GLP-1 for treatment of diabetes mellitus and irritable bowel syndrome
.
Adv Exp Med Biol
2015
;
849
:
23
38
[PubMed]
7.
Boss
AH
,
Petrucci
R
,
Lorber
D
.
Coverage of prandial insulin requirements by means of an ultra-rapid-acting inhaled insulin
.
J Diabetes Sci Technol
2012
;
6
:
773
779
[PubMed]
8.
Luzi
L
,
DeFronzo
RA
.
Effect of loss of first-phase insulin secretion on hepatic glucose production and tissue glucose disposal in humans
.
Am J Physiol
1989
;
257
:
E241
E246
[PubMed]
9.
Perley
MJ
,
Kipnis
DM
.
Plasma insulin responses to oral and intravenous glucose: studies in normal and diabetic sujbjects
.
J Clin Invest
1967
;
46
:
1954
1962
[PubMed]
10.
Mitrakou
A
,
Kelley
D
,
Mokan
M
, et al
.
Role of reduced suppression of glucose production and diminished early insulin release in impaired glucose tolerance
.
N Engl J Med
1992
;
326
:
22
29
[PubMed]
11.
Bruce
DG
,
Chisholm
DJ
,
Storlien
LH
,
Kraegen
EW
.
Physiological importance of deficiency in early prandial insulin secretion in non-insulin-dependent diabetes
.
Diabetes
1988
;
37
:
736
744
[PubMed]
12.
Bode BW, McGill JB, Lorber DL, Gross JL, Chang P-C, Bregman DB; Affinity 1 Study Group. Inhaled Technosphere insulin compared with injected prandial insulin in type 1 diabetes: a randomized 24-week trial. Diabetes Care 2015;38:2266–2273
13.
Lee
JJ
,
Dassau
E
,
Zisser
H
,
Harvey
RA
,
Jovanovič
L
,
Doyle
FJ
 3rd
.
In silico evaluation of an artificial pancreas combining exogenous ultrafast-acting Technosphere insulin with zone model predictive control
.
J Diabetes Sci Technol
2013
;
7
:
215
226
[PubMed]
14.
Zisser
H
,
Dassau
E
,
Lee
JJ
,
Harvey
RA
,
Bevier
W
,
Doyle
FJ
 3rd
.
Clinical results of an automated artificial pancreas using Technosphere inhaled insulin to mimic first-phase insulin secretion
.
J Diabetes Sci Technol
2015
;
9
:
564
572
[PubMed]
15.
Rosenstock J, Franco D, Korpachev V, et al.; Affinity 2 Study Group. Inhaled Technosphere insulin versus inhaled Technosphere placebo in insulin-naïve subjects with type 2 diabetes inadequately controlled on oral antidiabetes agents. Diabetes Care 2015;38:2274–2281
16.
Rosenstock
J
,
Bergenstal
R
,
Defronzo
RA
, et al.;
0008 Study Group
.
Efficacy and safety of Technosphere inhaled insulin compared with Technosphere powder placebo in insulin-naive type 2 diabetes suboptimally controlled with oral agents
.
Diabetes Care
2008
;
31
:
2177
2182
[PubMed]
17.
Holman
RR
,
Thorne
KI
,
Farmer
AJ
, et al.;
4-T Study Group
.
Addition of biphasic, prandial, or basal insulin to oral therapy in type 2 diabetes
.
N Engl J Med
2007
;
357
:
1716
1730
[PubMed]
18.
Bretzel
RG
,
Nuber
U
,
Landgraf
W
,
Owens
DR
,
Bradley
C
,
Linn
T
.
Once-daily basal insulin glargine versus thrice-daily prandial insulin lispro in people with type 2 diabetes on oral hypoglycaemic agents (APOLLO): an open randomised controlled trial
.
Lancet
2008
;
371
:
1073
1084
[PubMed]
19.
Heine
RJ
,
Van Gaal
LF
,
Johns
D
,
Mihm
MJ
,
Widel
MH
,
Brodows
RG
;
GWAA Study Group
.
Exenatide versus insulin glargine in patients with suboptimally controlled type 2 diabetes: a randomized trial
.
Ann Intern Med
2005
;
143
:
559
569
[PubMed]
20.
Buse
JB
,
Bergenstal
RM
,
Glass
LC
, et al
.
Use of twice-daily exenatide in basal insulin-treated patients with type 2 diabetes: a randomized, controlled trial
.
Ann Intern Med
2011
;
154
:
103
112
[PubMed]
21.
Bergenstal
RM
,
Johnson
M
,
Powers
MA
, et al
.
Adjust to target in type 2 diabetes: comparison of a simple algorithm with carbohydrate counting for adjustment of mealtime insulin glulisine
.
Diabetes Care
2008
;
31
:
1305
1310
[PubMed]
22.
Heinemann
L
,
Muchmore
DB
.
Ultrafast-acting insulins: state of the art
.
J Diabetes Sci Technol
2012
;
6
:
728
742
[PubMed]
23.
Cahn
A
,
Miccoli
R
,
Dardano
A
,
Del Prato
S
.
New forms of insulin and insulin therapies for the treatment of type 2 diabetes
.
Lancet Diabetes Endocrinol
2015
;
3
:
638
652
[PubMed]