Skip to main content
  • More from ADA
    • Diabetes
    • Clinical Diabetes
    • Diabetes Spectrum
    • ADA Standards of Medical Care
    • ADA Scientific Sessions Abstracts
    • BMJ Open Diabetes Research & Care
  • Subscribe
  • Log in
  • Log out
  • My Cart
  • Follow ada on Twitter
  • RSS
  • Visit ada on Facebook
Diabetes Care

Advanced Search

Main menu

  • Home
  • Current
    • Current Issue
    • Online Ahead of Print
    • Special Article Collections
    • ADA Standards of Medical Care
  • Browse
    • By Topic
    • Issue Archive
    • Saved Searches
    • Special Article Collections
    • ADA Standards of Medical Care
  • Info
    • About the Journal
    • About the Editors
    • ADA Journal Policies
    • Instructions for Authors
    • Guidance for Reviewers
  • Reprints/Reuse
  • Advertising
  • Subscriptions
    • Individual Subscriptions
    • Institutional Subscriptions and Site Licenses
    • Access Institutional Usage Reports
    • Purchase Single Issues
  • Alerts
    • E­mail Alerts
    • RSS Feeds
  • Podcasts
    • Diabetes Core Update
    • Special Podcast Series: Therapeutic Inertia
    • Special Podcast Series: Influenza Podcasts
    • Special Podcast Series: SGLT2 Inhibitors
    • Special Podcast Series: COVID-19
  • Submit
    • Submit a Manuscript
    • Journal Policies
    • Instructions for Authors
    • ADA Peer Review
  • More from ADA
    • Diabetes
    • Clinical Diabetes
    • Diabetes Spectrum
    • ADA Standards of Medical Care
    • ADA Scientific Sessions Abstracts
    • BMJ Open Diabetes Research & Care

User menu

  • Subscribe
  • Log in
  • Log out
  • My Cart

Search

  • Advanced search
Diabetes Care
  • Home
  • Current
    • Current Issue
    • Online Ahead of Print
    • Special Article Collections
    • ADA Standards of Medical Care
  • Browse
    • By Topic
    • Issue Archive
    • Saved Searches
    • Special Article Collections
    • ADA Standards of Medical Care
  • Info
    • About the Journal
    • About the Editors
    • ADA Journal Policies
    • Instructions for Authors
    • Guidance for Reviewers
  • Reprints/Reuse
  • Advertising
  • Subscriptions
    • Individual Subscriptions
    • Institutional Subscriptions and Site Licenses
    • Access Institutional Usage Reports
    • Purchase Single Issues
  • Alerts
    • E­mail Alerts
    • RSS Feeds
  • Podcasts
    • Diabetes Core Update
    • Special Podcast Series: Therapeutic Inertia
    • Special Podcast Series: Influenza Podcasts
    • Special Podcast Series: SGLT2 Inhibitors
    • Special Podcast Series: COVID-19
  • Submit
    • Submit a Manuscript
    • Journal Policies
    • Instructions for Authors
    • ADA Peer Review

Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity.

  1. M Stumvoll,
  2. A Mitrakou,
  3. W Pimenta,
  4. T Jenssen,
  5. H Yki-Järvinen,
  6. T Van Haeften,
  7. W Renn and
  8. J Gerich
  1. Abteilung IV, Medizinische Klinik der Universität Tübingen, Germany.
    Diabetes Care 2000 Mar; 23(3): 295-301. https://doi.org/10.2337/diacare.23.3.295
    PreviousNext
    • Article
    • Info & Metrics
    • PDF
    Loading

    Abstract

    OBJECTIVE: The oral glucose tolerance test (OGTT) has often been used to evaluate apparent insulin release and insulin resistance in various clinical settings. However, because insulin sensitivity and insulin release are interdependent, to what extent they can be predicted from an OGTT is unclear. RESEARCH DESIGN AND METHODS: We studied insulin sensitivity using the euglycemic-hyperinsulinemic clamp and insulin release using the hyperglycemic clamp in 104 nondiabetic volunteers who had also undergone an OGTT. Demographic parameters (BMI, waist-to-hip ratio, age) and plasma glucose and insulin values from the OGTT were subjected to multiple linear regression to predict the metabolic clearance rate (MCR) of glucose, the insulin sensitivity index (ISI), and first-phase (1st PH) and second-phase (2nd PH) insulin release as measured with the respective clamps. RESULTS: The equations predicting MCR and ISI contained BMI, insulin (120 min), and glucose (90 min) and were highly correlated with the measured MCR (r = 0.80, P < 0.00005) and ISI (r = 0.79, P < 0.00005). The equations predicting 1st PH and 2nd PH contained insulin (0 and 30 min) and glucose (30 min) and were also highly correlated with the measured 1st PH (r = 0.78, P < 0.00005) and 2nd PH (r = 0.79, P < 0.00005). The parameters predicted by our equations correlated better with the measured parameters than homeostasis model assessment for secretion and resistance, the delta30-min insulin/delta30-min glucose ratio for secretion and insulin (120 min) for insulin resistance taken from the OGTT. CONCLUSIONS: We thus conclude that predicting insulin sensitivity and insulin release with reasonable accuracy from simple demographic parameters and values obtained during an OGTT is possible. The derived equations should be used in various clinical settings in which the use of clamps or the minimal model would be impractical.

    PreviousNext
    Back to top

    In this Issue

    March 2000, 23(3)
    • Table of Contents
    • Index by Author
    Sign up to receive current issue alerts
    View Selected Citations (0)
    Download PDF
    Article Alerts
    Sign In to Email Alerts with your Email Address
    Email Article

    Thank you for your interest in spreading the word about Diabetes Care.

    NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

    Enter multiple addresses on separate lines or separate them with commas.
    Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity.
    (Your Name) has forwarded a page to you from Diabetes Care
    (Your Name) thought you would like to see this page from the Diabetes Care web site.
    CAPTCHA
    This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
    Citation Tools
    Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity.
    M Stumvoll, A Mitrakou, W Pimenta, T Jenssen, H Yki-Järvinen, T Van Haeften, W Renn, J Gerich
    Diabetes Care Mar 2000, 23 (3) 295-301; DOI: 10.2337/diacare.23.3.295

    Citation Manager Formats

    • BibTeX
    • Bookends
    • EasyBib
    • EndNote (tagged)
    • EndNote 8 (xml)
    • Medlars
    • Mendeley
    • Papers
    • RefWorks Tagged
    • Ref Manager
    • RIS
    • Zotero
    Add to Selected Citations
    Share

    Use of the oral glucose tolerance test to assess insulin release and insulin sensitivity.
    M Stumvoll, A Mitrakou, W Pimenta, T Jenssen, H Yki-Järvinen, T Van Haeften, W Renn, J Gerich
    Diabetes Care Mar 2000, 23 (3) 295-301; DOI: 10.2337/diacare.23.3.295
    del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
    • Tweet Widget
    • Facebook Like
    • Google Plus One

    Jump to section

    • Article
    • Info & Metrics
    • PDF

    Related Articles

    Cited By...

    Similar Articles

    Navigate

    • Current Issue
    • Standards of Care Guidelines
    • Online Ahead of Print
    • Archives
    • Submit
    • Subscribe
    • Email Alerts
    • RSS Feeds

    More Information

    • About the Journal
    • Instructions for Authors
    • Journal Policies
    • Reprints and Permissions
    • Advertising
    • Privacy Policy: ADA Journals
    • Copyright Notice/Public Access Policy
    • Contact Us

    Other ADA Resources

    • Diabetes
    • Clinical Diabetes
    • Diabetes Spectrum
    • Scientific Sessions Abstracts
    • Standards of Medical Care in Diabetes
    • BMJ Open - Diabetes Research & Care
    • Professional Books
    • Diabetes Forecast

     

    • DiabetesJournals.org
    • Diabetes Core Update
    • ADA's DiabetesPro
    • ADA Member Directory
    • Diabetes.org

    © 2021 by the American Diabetes Association. Diabetes Care Print ISSN: 0149-5992, Online ISSN: 1935-5548.