Skip to main content
  • More from ADA
    • Diabetes
    • Clinical Diabetes
    • Diabetes Spectrum
    • ADA Standards of Medical Care
    • ADA Scientific Sessions Abstracts
    • BMJ Open Diabetes Research & Care
  • Subscribe
  • Log in
  • My Cart
  • Follow ada on Twitter
  • RSS
  • Visit ada on Facebook
Diabetes Care

Advanced Search

Main menu

  • Home
  • Current
    • Current Issue
    • Online Ahead of Print
    • Special Article Collections
    • ADA Standards of Medical Care
  • Browse
    • By Topic
    • Issue Archive
    • Saved Searches
    • Special Article Collections
    • ADA Standards of Medical Care
  • Info
    • About the Journal
    • About the Editors
    • ADA Journal Policies
    • Instructions for Authors
    • Guidance for Reviewers
  • Reprints/Reuse
  • Advertising
  • Subscriptions
    • Individual Subscriptions
    • Institutional Subscriptions and Site Licenses
    • Access Institutional Usage Reports
    • Purchase Single Issues
  • Alerts
    • E­mail Alerts
    • RSS Feeds
  • Podcasts
    • Diabetes Core Update
    • Special Podcast Series: Therapeutic Inertia
    • Special Podcast Series: Influenza Podcasts
    • Special Podcast Series: SGLT2 Inhibitors
    • Special Podcast Series: COVID-19
  • Submit
    • Submit a Manuscript
    • Journal Policies
    • Instructions for Authors
    • ADA Peer Review
  • More from ADA
    • Diabetes
    • Clinical Diabetes
    • Diabetes Spectrum
    • ADA Standards of Medical Care
    • ADA Scientific Sessions Abstracts
    • BMJ Open Diabetes Research & Care

User menu

  • Subscribe
  • Log in
  • My Cart

Search

  • Advanced search
Diabetes Care
  • Home
  • Current
    • Current Issue
    • Online Ahead of Print
    • Special Article Collections
    • ADA Standards of Medical Care
  • Browse
    • By Topic
    • Issue Archive
    • Saved Searches
    • Special Article Collections
    • ADA Standards of Medical Care
  • Info
    • About the Journal
    • About the Editors
    • ADA Journal Policies
    • Instructions for Authors
    • Guidance for Reviewers
  • Reprints/Reuse
  • Advertising
  • Subscriptions
    • Individual Subscriptions
    • Institutional Subscriptions and Site Licenses
    • Access Institutional Usage Reports
    • Purchase Single Issues
  • Alerts
    • E­mail Alerts
    • RSS Feeds
  • Podcasts
    • Diabetes Core Update
    • Special Podcast Series: Therapeutic Inertia
    • Special Podcast Series: Influenza Podcasts
    • Special Podcast Series: SGLT2 Inhibitors
    • Special Podcast Series: COVID-19
  • Submit
    • Submit a Manuscript
    • Journal Policies
    • Instructions for Authors
    • ADA Peer Review
Clinical Care/Education/Nutrition

A Pilot Study of the Continuous Glucose Monitoring System

Clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects

  1. Francine R. Kaufman, MD,
  2. Leena C. Gibson, MA,
  3. Mary Halvorson, RN, MSN, CDE,
  4. Sue Carpenter, BA, RN, CDE,
  5. Lynda K. Fisher, MD and
  6. Pisit Pitukcheewanont, MD
  1. Division of Endocrinology and Metabolism, Childrens Hospital Los Angeles and the Department of Pediatrics, University of Southern California School of Medicine, Los Angeles, California
    Diabetes Care 2001 Dec; 24(12): 2030-2034. https://doi.org/10.2337/diacare.24.12.2030
    PreviousNext
    • Article
    • Figures & Tables
    • Info & Metrics
    • PDF
    Loading

    Clinical decisions and glycemic control after its use in pediatric type 1 diabetic subjects

    Abstract

    OBJECTIVE—To determine whether the continuous glucose monitoring system (CGMS) (MiniMed, Sylmar, CA) could be used to make clinical decisions and whether it has an impact on glycemia in pediatric type 1 diabetic subjects.

    RESEARCH DESIGN AND METHODS—Pediatric subjects were recruited if they had HbA1c >8.0% with management problems (n = 35) or episodes of severe or nocturnal hypoglycemia or hypoglycemia unawareness associated with HbA1c ≤8.0% (n = 12). A total of 47 patients with a mean HbA1c value of 8.6 ± 1.6% (mean age 11.8 ± 4.6 years, youngest 2.7 years, and diabetes duration 5.5 ± 3.5 years) on three to four insulin injections/day (n = 24) or insulin pump therapy (n = 23) were followed with the CGMS for a mean of 69.5 ± 28 h. Comparisons were made between the number of high (>150 mg/dl) and low (<70 mg/dl) glucose patterns discerned with the sensor or the logbook, and HbA1c levels were evaluated.

    RESULTS—In patients on injection therapy, 30 high or low glucose patterns were discerned with the logbook records and 120 patterns with the CGMS. Specific alterations of the diabetes regimen were made. An overall significant change in HbA1c, from 3 months before wearing the sensor to 6 months after (analysis of variance 0.04), was found in the subjects. Post hoc analysis showed a significant change in HbA1c from 8.6 ± 1.5% at baseline to 8.4 ± 1.3% at 3 months (paired Student’s t test 0.03).

    CONCLUSIONS—The CGMS can be used by pediatric patients to detect abnormal patterns of glycemia. The information that was obtained could be used to alter the diabetes regimen and impact glycemic outcome.

    • ANOVA, analysis of variance
    • CGMS, continuous glucose monitoring system
    • CSII, continuous subcutaneous insulin infusion

    The goal of the management of type 1 diabetes in children and youth is to maintain blood glucose and HbA1c levels as near to normal as possible (1). Although this goal is difficult to achieve for all patients with type 1 diabetes, it is even more challenging for pediatric subjects. Children and adolescents often have fluctuations in blood glucose level, and their activity pattern and food intake are often erratic and unpredictable. In 1998–1999, data from our large, urban center at Childrens Hospital Los Angeles for over 1,000 patients who had received diabetes education and had access to the health team for advice on diabetes management showed that the mean HbA1c level was 8.2%.

    The diabetes regimen followed by our patients consisted of taking multiple insulin injections per day or using continuous subcutaneous insulin infusion (CSII) (2). As part of the diabetes regimen, our patients are advised to obtain at least four finger-stick glucose measurements each day. This allows for adjustment of insulin dosage, food intake, and activity level to maintain glycemia within the individualized target range, which is dependent on age, developmental stage, and the ability to recognize hypoglycemia (3). Currently, one of the main obstacles to achieving glycemic control is that blood glucose is intermittently measured. Continuous glucose monitoring would eliminate the fact that finger-stick measurements can only provide information regarding a few minutes of each day and cannot be used to easily identify patterns of abnormal glycemia.

    Recently, the MiniMed continuous glucose monitoring system (CGMS), a light-weight, portable, minimally invasive system, was developed (4). This system continuously measures subcutaneous tissue interstitial glucose levels, recording values on average every 5 min within a range of 40–400 mg/dl. Glucose values obtained with the CGMS have been shown to correlate with laboratory measurements of plasma glucose concentrations (5) and home glucose values (6). With glucose fluctuations, it has been shown that there is a 5-min lag time with the CGMS. This lag time appears to be inconsequential in the present study because it retrospectively evaluates glucose levels.

    The CGMS is comprised of four components. The glucose sensor, an electrode impregnated with glucose oxidase, is subcutaneously placed via a flexible catheter that can be easily tolerated for 3 days. Additional sensors can be worn to provide >3 days of data. The sensor is seamlessly connected via a cable to the monitor, which is light-weight and worn on clothing or a belt. The monitor collects and stores the glucose data until it is downloaded into the com-station, where glucose values are displayed. A typical 3-day tracing of the sensor-wear can then be analyzed.

    The initial studies on the CGMS were performed in adult subjects (7,8). These studies showed that the system is well tolerated by adult type 1 diabetic patients. Additional research has shown that the information obtained allows the patient and health care team to adjust the timing and dosage of insulin and the nutrition plan to improve glycemic control, resulting in an average decrease in HbA1c from 9.9 to 8.8% after 5 weeks (9). Chase et al. (10) studied continuous glucose monitoring in pediatric subjects to determine whether it could help recognize nocturnal hypoglycemia or lower HbA1c. A small cohort of children (n = 11) were randomized to the CGMS or a control group for 30 days, during which time the CGMS group used six 3-day sensors. The CGMS revealed asymptomatic hypoglycemia in study patients, and HbA1c was decreased by 0.36 ± 0.07% in the CGMS group compared with 0.2 ± 0.2% in the control group.

    The purpose of the present study was to determine whether the CGMS could be used by a larger group of pediatric patients with type 1 diabetes. Children and youth were recruited to use the CGMS to determine whether high and low patterns of glycemia could be identified. The initial subjects chosen for this study were those with less than optimal glycemic control, as determined by HbA1c, or a history of severe hypoglycemia, hypoglycemia unawareness, or nocturnal hypoglycemia. HbA1c levels were measured at 3 months before continuous glucose monitoring, at placement of the CGMS, and at 3 and 6 months post sensor-wear and compared to see whether adjusting the diabetes regimen with the information obtained from the CGMS led to a change in glycemic outcome.

    RESEARCH DESIGN AND METHODS

    Patient selection

    Fifty pediatric patients with type 1 diabetes were recruited for this study during routine clinical visits to the Comprehensive Diabetes Center at Childrens Hospital Los Angeles during a 6-month period at the end of 1999 and the beginning of 2000. Patients were eligible to enter if they had an HbA1c value >8.0% (n = 35) associated with one of the following clinical problems: elevated fasting blood glucose levels or suspected dawn phenomenon; glycemic excursion with exercise; insulin dosage >1–1.5 units · kg–1 · day–1 for prepubertal and pubertal children, respectively; widely fluctuating blood glucose levels; or erratic response to blood glucose correction. Subjects with recurrent hypoglycemia, hypoglycemia unawareness, or suspected nocturnal hypoglycemia (n = 12) combined with an HbA1c level ≤8.0% were also eligible. After being shown the sensor and receiving an explanation as to what a 3-day sensor-wear entailed, all subjects agreed to wear the sensor for a 3-day period. Pump patients were given the option to insert a second sensor. A total of 47 subjects/parents agreed to participate and signed informed consent. The mean age of the subjects was 11.8 ± 4.6 years (range 2.7–29.1). There were 18 male and 29 female subjects. The patients had a mean duration of diabetes of 5.5 ± 3.5 years (range 0.8–20) and a mean baseline HbA1c of 8.6 ± 1.6% (6.3–12.9). A total of 24 subjects took three to four insulin injections per day, and the remaining 23 subjects used CSII.

    Study protocol

    Patients and parents were brought to the outpatient clinic at Childrens Hospital Los Angeles for a 2-h training and evaluation session. Sensor placement was done by one of two Certified Diabetes Educators after pretreatment of the abdominal skin where the sensor was placed with EMLA Cream (Astra Pharmaceuticals, Wayne, PA). Calibration of the sensor was accomplished by following the protocol established and outlined in the MiniMed CGMS manual. Four monitors were used during the study.

    During continuous glucose monitoring, patients/parents were instructed to measure a minimum of four finger-stick blood glucose levels per day and to record glucose values, meals, insulin doses, exercise periods, and symptomatic hypoglycemia in a logbook. They were also instructed on how to code these events into the monitor.

    At the completion of the CGMS period, the system was returned and the data downloaded via the com-station to determine glucose patterns. Logbooks were also analyzed for glucose patterns. A high glucose pattern was defined if at least 2 of 3 days or >50% of glucose levels were >150 mg/dl, and a low-glucose pattern was defined if at least 2 of 3 days or >50% of values were <70 mg/dl during one of the eight time periods. The eight time periods were: breakfast, postbreakfast, lunch, postlunch and afternoon snack, dinner, bedtime, midnight, and 3:00 am. The number of high and low patterns determined by logbooks were compared with the number of high and low patterns seen with the CGMS.

    The CGMS patterns were reviewed with the patient/parent, and recommended changes in the diabetes regimen to improve glycemia were discussed. The following nine types of recommendations were made from CGMS analyses: 1) change in one or more bolus or rapid-acting insulin dosage; 2) change in one or more basal or intermediate/long-acting insulin dosage; 3) change in the correction algorithm (3); 4) alteration in the approach to exercise to include change in carbohydrate management (11); 5) reinforcing treatment algorithm for hypoglycemia to include rechecking, adding extra carbohydrate, and protein (11); 6) change in early morning basal rate (pump patients) or bedtime insulin dosage and/or timing (injection patients) due to the dawn phenomenon; 7) increase in meal bolus and timing of injection after the meal (injection patients) or adding square-wave bolus (pump patients) for high-fat meals; 8) increase in meal insulin dosage for high glycemic foods; and 9) referral for counseling to improve adherence with diabetes regimen. Data were analyzed to determine the percentage of patients advised to perform each of these nine recommendations. HbA1c levels were obtained with the DCA 2000 (Bayer, Tarrytown, NY) (normal range 3–6%) 3 months before CGMS, at the time of sensor placement, and at 3 and 6 months post sensor-wear.

    Descriptive statistical analysis was performed on the sample population. This was done to determine the frequency of sensor findings, differences between information obtained from the CGMS and logbooks, and treatment recommendations. Repeated measures of analysis of variance (ANOVA) were used to evaluate change in HbA1c in subjects. The paired Student’s t test was used to determine differences in HbA1c levels before and after sensor placement.

    RESULTS

    All subjects tolerated the CGMS for at least 3 days. The mean duration of sensor-wear was 69.5 ± 28 h (range 29–111). Patients coded a mean of 49 ± 24 events (meals, exercise, and symptomatic hypoglycemia) into the monitor during CGMS use. There was a mean of 18.5 ± 8.0 finger-stick glucose levels recorded in logbooks, resulting in a mean of 4.3 ± 0.7 measurements/day. There was a mean of 1.1 ± 0.9 interruptions in the sensor tracings per subject that were <3 h in duration and did not interfere with data analysis.

    Table 1 shows the number of high and low patterns that could be determined using the CGMS as compared with that from the logbook for all subjects and for those on CSII and injection therapy. As shown in Table 1, high and low pattern identification was greater with the CGMS (191 patterns) than with logbook records (42 patterns) for all patients and for those using injection (120 patterns with CGMS and 30 with logbook) and insulin pump therapy (71 patterns with CGMS and 12 with logbook). Overall, there were 1.8 times more abnormal patterns detected for subjects on injection therapy compared with subjects using insulin pump therapy (Table 1).

    With the CGMS, a mean of 1.17 ± 1.3 asymptomatic nocturnal hypoglycemic events during the bedtime, night, and early morning time periods were noted per patient, with 83% of subjects having at least one episode. Ten (22%) subjects were found to have an elevation in glucose level during the early morning period that was consistent with the dawn phenomenon. During sensor-wear, 15 (32%) patients were found to have a high breakfast pattern, 15 (32%) had a high lunch pattern, and 12 (25%) had a high dinner pattern, whereas 2 (4%) had a low breakfast pattern, 3 (6%) had a low lunch pattern, and 2 (4%) had a low dinner pattern. In contrast, there were no low postmeal patterns. Eight (17%) patients had a high postbreakfast pattern, 11 (23%) had a high postlunch/afternoon snack pattern, and 9 (19%) had a high bedtime pattern.

    Figure 1 illustrates the percentage of patients with whom a recommendation to alter their diabetes regimen was discussed after using the CGMS. As shown, of the nine types of recommendations of how to alter the diabetes regimen, the most common was to make a change in one or more of the subject’s basal insulin dosages for those on CSII and in one or more of the long- or intermediate-acting insulin doses for those taking injections. This was followed by recommendations to change one or more bolus or rapid-acting insulin dose, to change hypoglycemia treatment, and to change the correction algorithm. There was a mean of 3.3 ± 0.8 recommendations per patient.

    Table 2 shows the HbA1c results 3 months before, at baseline, and 3 and 6 months post-CGMS for all patients and those using CSII and injection therapy. Repeated measures of ANOVA showed significance in HbA1c at these intervals (P = 0.04). Post hoc analysis showed a significant change between time of sensor placement and 3 months post-CGMS as in table 2 (P = 0.03, paired Student’s t test). Comparing HbA1c levels at the time of sensor placement and at 3 months, 27 patients (25 with HbA1c >8.0% and 2 with HbA1c ≤8.0% at baseline) had a reduction in HbA1c by a mean of 0.66%. These subjects had a mean baseline HbA1c of 9.08 ± 1.1%. Sixteen subjects (seven with HbA1c >8.0% and nine with HbA1c ≤8.0% at baseline) had an increase in HbA1c by a mean of 0.43%. Their mean baseline HbA1c was 7.88 ± 0.9%. In four children (three with HbA1c >8.0% and one with ≤8.0% at baseline), there was no change in HbA1c between 3 months before and 3 months after continuous glucose monitoring.

    CONCLUSIONS

    This study showed that the CGMS was well tolerated and beneficial in pediatric type 1 diabetic patients. Patients, some of whom were very young, were able to wear the sensor without problems, and events such as meals, exercise, and symptoms of hypoglycemia were coded in the sensor during daily activities as advised. The glucose tracings derived from the CGMS enabled diabetes care providers as well as patients and their families to discern distinct patterns of abnormal glycemia regardless of whether they were using CSII or insulin injection therapy. The information obtained led to recommendations for adjustment of the diabetes regimen. Follow-up studies determined that these alterations led to improved glycemic control as assessed by mean HbA1c levels. Although HbA1c levels were statistically unchanged when retrospectively compared 3 months before and at the time of CGMS placement, these values were improved at 3 months post-CGMS and sustained at 6 months. Because HbA1c levels had been previously correlated with the number of finger-stick glucose levels obtained in a French study that evaluated 2,579 children with type 1 diabetes (12), it was anticipated that the larger number of glucose measurements done with the CGMS would improve the glycemic outcome of pediatric subjects.

    The CGMS revealed that one or more basal, bolus, and correction insulin dosage was not optimal in a large number of patients. At least one-quarter to one-third of subjects were found to have a high premeal pattern (at one or more premeal time periods), and 17–23% were found to have a high postmeal pattern (at one or more postmeal time periods). These findings necessitated increasing one or more basal and bolus insulin dosage in 87 and 70% of subjects, respectively, as well as increasing the dose of insulin used to correct a high glucose level outside of the target range in 32% of patients. It is likely that these recommendations on how to decrease the large number of high pre- and postmeal patterns positively impacted on the follow-up HbA1c. At the present time, it is controversial whether fasting or postprandial glycemia has more impact on diabetes control (13). With follow-up sensor-wear, it might be possible to determine the relative importance of pre- versus postmeal glucose levels on diabetes outcome. Therefore, the CGMS might prove to have a role in clinical diabetes research that is aimed at addressing areas of controversy in diabetes management.

    As recently described by Bode et al. (14), during sensor-wear, nocturnal hypoglycemia and the dawn phenomenon are frequently found but are not apparent with finger-stick monitoring alone because finger-sticks are rarely done at those times. In our patients, the CGMS confirmed what has been described in previous research studies, which showed a high occurrence of asymptomatic nocturnal hypoglycemia in pediatric subjects who measured nighttime blood glucose levels as part of a research protocol (15,16). In our subjects, the finding of nighttime hypoglycemia lead to the recommendation to decrease basal insulin rates during the night for pump patients and evening intermediate-acting insulin for patients on injection therapy. Reducing insulin dosages might have helped decrease further episodes of hypoglycemia by ameliorating hypoglycemia unawareness, which results in part from recurrent low blood glucose (17).

    We were surprised by the number of recommendations that were made to alter the diabetes regimen in addition to changing insulin dosages. Over one-half of our subjects did not appropriately manage hypoglycemia. This could be discerned when hypoglycemia was detected by a finger-stick glucose measurement and then subsequent glucose levels were evaluated by the CGMS. Approximately 30% of subjects did not recheck to insure that hypoglycemia had been resolved. In addition to this pattern of persistent hypoglycemia, at least one-quarter of the time, a recurrent episode of hypoglycemia occurred after treatment.

    The CGMS data also revealed the frequent occurrence of hypoglycemia associated with exercise in many of our subjects. Some subjects experienced hyperglycemia after the completion of exercise as a result of excess carbohydrate ingestion at the time of hypoglycemia or as a result of disconnecting the insulin pump during exercise. The CGMS data indicated that if glycemic control is to be optimized in the future, patients/families must consider whether the food that is being ingested is high in fat or carbohydrates in order to appropriately alter insulin doses and insulin delivery to account for meal composition. Finally, it should be noted that fewer abnormal patterns were detected in subjects using insulin pumps compared with those taking insulin injections. This suggests that better glycemic control might be achieved with CSII compared with multiple-injection therapy.

    Although there was a significant change in HbA1c over the time intervals, the mean decrease for our study population was modest (0.2 and 0.3% at 3 and 6 months, respectively). These findings were similar to those of Chase et al. (10). This can be explained by the fact that one-quarter of the subjects entered the study with HbA1c values ≤8.0%. Many subjects in this group had either a small rise (n = 9) or no change in HbA1c (n = 1) after 3 months, presumably due to a decrease in hypoglycemia. On the other hand, 25 patients with elevated baseline HbA1c levels >8.0% (mean 9.08%) had a decrease in HbA1c after the diabetes regimen was altered (mean decrease 0.66%). It is difficult to be sure that the overall improvement in HbA1c and diabetes management in our subjects that was apparent at 3 months post-CGMS and still evident at 6 months post-CGMS was due to instituting the recommendations that came from sensor-wear itself. Our subjects showed no change in HbA1c over the 3-month time period before sensor use despite undergoing a multidisciplinary clinic visit that was focused on altering the diabetes regimen to improve glycemic control. However, they did experience improvement in HbA1c after a self-management counseling session in which the CGMS was used. This suggests that using the sensor and altering each subject’s diabetes regimen as a result of the information obtained from the sensor tracing was an effective method for decreasing HbA1c.

    The data provided by the CGMS for 3 days should be used to help optimize glycemia in pediatric patients with type 1 diabetes. The wealth of information obtained showed pre- and postprandial glucose levels, incidence and timing of hypo- and hyperglycemia, and the effect of exercise and food composition. These data were used to make specific recommendations that improved HbA1c values in subjects for a 3- to 6-month time period. Whether a more prolonged benefit will be appreciated or repeat continuous glucose monitoring will be required needs to be investigated.

    Figure 1—
    • Download figure
    • Open in new tab
    • Download powerpoint
    Figure 1—

    Percentage of patients given each of nine recommendations on how to alter their diabetes regimen.

    View this table:
    • View inline
    • View popup
    Table 1—

    Number of high and low patterns for all patients and those on CSII and injections

    View this table:
    • View inline
    • View popup
    Table 2—

    HbA1c for all subjects and those on CSII and injections

    Acknowledgments

    This study was presented in part at the American Diabetes Association annual meeting, San Antonio, TX, June 2000.

    Footnotes

    • Address correspondence and reprint requests to Francine R. Kaufman, 4650 Sunset Blvd, MS #61, Los Angeles, CA 90027. E-mail: fkaufman{at}chla.usc.edu.

      Received for publication 27 December 2000 and accepted in revised form 17 August 2001.

      F.R.C. has received consultantships from and served on advisory panels for Minimed, Integ, Novo Nordisk, Genentech, Medisense Ketone, Inverness, Johnson & Johnson, Takeda Pharmaceuticals, Cygnus, Ortho McNeil, and Amylin; is a stockholder in MiniMed and Clincal Products; has received grant/research support from Bristol Myers Squibb, Genentech, Pharmacia & Upjohn, Eli Lilly, Novo Nordisk, Pfizer, MiniMed, and Takeda Pharmaceuticals; and is on the the speaker’s bureau for Eli Lilly, Novo Nordisk, and MiniMed. M.H. is a stock shareholder in MiniMed and Inhale; has received honoraria for speaking engagements from MiniMed, Novo Nordisk, Lilly, and Medisense; and has received grant/research support from MiniMed, Lilly, Starbright, and NovoNordisk. S.C. is a stockholder in MiniMed.

      A table elsewhere in this issue shows conventional and Système International (SI) units and conversion factors for many substances.

    References

    1. ↵
      Kaufman FR: Diabetes mellitus. Pediatr Rev 18: 383–392, 1997
      OpenUrlFREE Full Text
    2. ↵
      Kaufman FR, Halvorson M, Miller D, Mackensie M, Fisher LK, Pitukcheewanont P: Insulin pump therapy in type 1 pediatric patients: now and into the year 2000. Diabete Metab Res Rev15:338–352, 1999
    3. ↵
      Kaufman FR, Halvorson M, Carpenter S: Use of a plastic insulin dosage guide to correct blood glucose levels out of the target range and for carbohydrate counting in children with type 1 diabetes. Diabetes Care 22:1252–1257, 1999
      OpenUrlAbstract
    4. ↵
      Mastrototaro JJ: The MiniMed continuous glucose monitoring system (CGMS). J Pediatr Endocrinol Metab 12(Suppl. 3):751–758, 1999
      OpenUrl
    5. ↵
      Rebrin K, Steil GM, Van Antwerp WP, Mastrototaro JJ: Subcutaneous glucose predicts plasma glucose independent of insulin: implications for continuous monitoring. Am J Physiol 277: E561–E571, 1999
    6. ↵
      Gross TM, Bode BW, Einhorn D, Kayne DM, Reed JH, White NH, Mastrototaro JJ: Performance evaluation of the MiniMed continuous glucose monitoring system during patient home use. Diabetes Technol Ther 2:49–56, 2000
      OpenUrlPubMed
    7. ↵
      Mastortotoro J, Levy R, Georges L-P, White N, Mestman J: Clinical results from a continuous glucose sensor multi-center study (Abstract). Diabetes 47:A61, 1998
      OpenUrl
    8. ↵
      Food and Drug Administration: Review Criteria Assessment of Portable Blood Glucose Monitoring in vitro Diagnostic Devices Using Glucose Oxidase, Dehydrogenase or Hexokinase Methodology, 1997. Available from http://fda.gov/cdrh/ode/gluc.html.
    9. ↵
      Bode BW, Gross TM, Thornton KR, Mastrototoro JM: Continuous glucose monitoring used to adjust diabetes therapy improves glycosylated hemoglobin: a pilot study, Diabetes Research and Clinical Practice. Diabetes Res Clin Pract 46:183–190, 1999
      OpenUrlCrossRefPubMedWeb of Science
    10. ↵
      Chase HP, Kim LM, Owen SL, MacKenzie TA, Klingensmith GJ, Murtfield R, Garg SK: Continuous subcutaneous glucose monitoring in children with type 1 diabetes. Pediatrics 107:222–226, 2001
      OpenUrlAbstract/FREE Full Text
    11. ↵
      Kaufman FR, Halvorson M: New trends in managing type 1 diabetes. Contemp Pediatr 16:112–123, 1999
      OpenUrl
    12. ↵
      Rosilio M, Cotton JB, Wieliczko MC, Gendrault B, Carel JC, Couvaras O, Ser N, Bougneres PF, Gillet P, Soskin S, Garandeau P, Stuckens C, Le luyer B, Jos J, Bony-Trifunovic H, Bertrand AM, Leturcq F, Lafuma A, the French Pediatric Diabetes Group, Bougneres P-F: Factors associated with glycemic control: a cross-sectional nationwide study in 2,579 French children with type 1 diabetes. Diabetes Care 21:1146–1153, 1998
      OpenUrlAbstract/FREE Full Text
    13. ↵
      Bastyr EJ, Stuart CA, Schwartz S, Graf CJ, Zagar A, Robertson KE, for the IOEZ Study Group: Therapy focused on lowering postprandial glucose, not fasting glucose, may be superior for lowering HbA1c. Diabetes Care 23:1236–1241, 2000
      OpenUrlAbstract/FREE Full Text
    14. ↵
      Bode BW, Sabbah H, Robertson DG, Tolbert LC, Fredrickson LP: New opportunities for therapeutic changes with continuous glucose sensing. Diabetes Spectrum 13:171–174, 2000
      OpenUrl
    15. ↵
      Porter PA, Keating B, Byrne G, Jones TW: Incidence and predictive criteria of nocturnal hypoglycemia in young children with insulin-dependent diabetes mellitus. J Pediatr 130:366–372, 1997
      OpenUrlCrossRefPubMedWeb of Science
    16. ↵
      Beregszaszi M, Tubiani-Rufa N, Benali K, Noel M, Bloch J, Czernichow P: Nocturnal hypoglycemia in children and adolescents with insulin-dependent diabetes mellitus: prevalence and risk factors. J Pediatr 131:27–33, 1997
      OpenUrlCrossRefPubMed
    17. ↵
      Cryer P: Hypoglycemia unawareness in IDDM. Diabetes Care 16:40–47, 1993
      OpenUrlAbstract/FREE Full Text
    PreviousNext
    Back to top
    Diabetes Care: 24 (12)

    In this Issue

    December 2001, 24(12)
    • Table of Contents
    • About the Cover
    • Index by Author
    Sign up to receive current issue alerts
    View Selected Citations (0)
    Print
    Download PDF
    Article Alerts
    Sign In to Email Alerts with your Email Address
    Email Article

    Thank you for your interest in spreading the word about Diabetes Care.

    NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

    Enter multiple addresses on separate lines or separate them with commas.
    A Pilot Study of the Continuous Glucose Monitoring System
    (Your Name) has forwarded a page to you from Diabetes Care
    (Your Name) thought you would like to see this page from the Diabetes Care web site.
    CAPTCHA
    This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
    Citation Tools
    A Pilot Study of the Continuous Glucose Monitoring System
    Francine R. Kaufman, Leena C. Gibson, Mary Halvorson, Sue Carpenter, Lynda K. Fisher, Pisit Pitukcheewanont
    Diabetes Care Dec 2001, 24 (12) 2030-2034; DOI: 10.2337/diacare.24.12.2030

    Citation Manager Formats

    • BibTeX
    • Bookends
    • EasyBib
    • EndNote (tagged)
    • EndNote 8 (xml)
    • Medlars
    • Mendeley
    • Papers
    • RefWorks Tagged
    • Ref Manager
    • RIS
    • Zotero
    Add to Selected Citations
    Share

    A Pilot Study of the Continuous Glucose Monitoring System
    Francine R. Kaufman, Leena C. Gibson, Mary Halvorson, Sue Carpenter, Lynda K. Fisher, Pisit Pitukcheewanont
    Diabetes Care Dec 2001, 24 (12) 2030-2034; DOI: 10.2337/diacare.24.12.2030
    del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
    • Tweet Widget
    • Facebook Like
    • Google Plus One

    Jump to section

    • Article
      • Abstract
      • RESEARCH DESIGN AND METHODS
      • RESULTS
      • CONCLUSIONS
      • Acknowledgments
      • Footnotes
      • References
    • Figures & Tables
    • Info & Metrics
    • PDF

    Related Articles

    Cited By...

    More in this TOC Section

    • Increased Second Trimester Maternal Glucose Levels Are Related to Extremely Large-for-Gestational-Age Infants in Women With Type 1 Diabetes
    • An Evaluation of Methods of Assessing Impaired Awareness of Hypoglycemia in Type 1 Diabetes
    • Effects of Isoflavone Dietary Supplementation on Cardiovascular Risk Factors in Type 2 Diabetes
    Show more Clinical Care/Education/Nutrition

    Similar Articles

    Navigate

    • Current Issue
    • Standards of Care Guidelines
    • Online Ahead of Print
    • Archives
    • Submit
    • Subscribe
    • Email Alerts
    • RSS Feeds

    More Information

    • About the Journal
    • Instructions for Authors
    • Journal Policies
    • Reprints and Permissions
    • Advertising
    • Privacy Policy: ADA Journals
    • Copyright Notice/Public Access Policy
    • Contact Us

    Other ADA Resources

    • Diabetes
    • Clinical Diabetes
    • Diabetes Spectrum
    • Scientific Sessions Abstracts
    • Standards of Medical Care in Diabetes
    • BMJ Open - Diabetes Research & Care
    • Professional Books
    • Diabetes Forecast

     

    • DiabetesJournals.org
    • Diabetes Core Update
    • ADA's DiabetesPro
    • ADA Member Directory
    • Diabetes.org

    © 2021 by the American Diabetes Association. Diabetes Care Print ISSN: 0149-5992, Online ISSN: 1935-5548.