Skip to main content
  • More from ADA
    • Diabetes
    • Clinical Diabetes
    • Diabetes Spectrum
    • ADA Standards of Medical Care
    • ADA Scientific Sessions Abstracts
    • BMJ Open Diabetes Research & Care
  • Subscribe
  • Log in
  • My Cart
  • Follow ada on Twitter
  • RSS
  • Visit ada on Facebook
Diabetes Care

Advanced Search

Main menu

  • Home
  • Current
    • Current Issue
    • Online Ahead of Print
    • Special Article Collections
    • ADA Standards of Medical Care
  • Browse
    • By Topic
    • Issue Archive
    • Saved Searches
    • Special Article Collections
    • ADA Standards of Medical Care
  • Info
    • About the Journal
    • About the Editors
    • ADA Journal Policies
    • Instructions for Authors
    • Guidance for Reviewers
  • Reprints/Reuse
  • Advertising
  • Subscriptions
    • Individual Subscriptions
    • Institutional Subscriptions and Site Licenses
    • Access Institutional Usage Reports
    • Purchase Single Issues
  • Alerts
    • E­mail Alerts
    • RSS Feeds
  • Podcasts
    • Diabetes Core Update
    • Special Podcast Series: Therapeutic Inertia
    • Special Podcast Series: Influenza Podcasts
    • Special Podcast Series: SGLT2 Inhibitors
    • Special Podcast Series: COVID-19
  • Submit
    • Submit a Manuscript
    • Journal Policies
    • Instructions for Authors
    • ADA Peer Review
  • More from ADA
    • Diabetes
    • Clinical Diabetes
    • Diabetes Spectrum
    • ADA Standards of Medical Care
    • ADA Scientific Sessions Abstracts
    • BMJ Open Diabetes Research & Care

User menu

  • Subscribe
  • Log in
  • My Cart

Search

  • Advanced search
Diabetes Care
  • Home
  • Current
    • Current Issue
    • Online Ahead of Print
    • Special Article Collections
    • ADA Standards of Medical Care
  • Browse
    • By Topic
    • Issue Archive
    • Saved Searches
    • Special Article Collections
    • ADA Standards of Medical Care
  • Info
    • About the Journal
    • About the Editors
    • ADA Journal Policies
    • Instructions for Authors
    • Guidance for Reviewers
  • Reprints/Reuse
  • Advertising
  • Subscriptions
    • Individual Subscriptions
    • Institutional Subscriptions and Site Licenses
    • Access Institutional Usage Reports
    • Purchase Single Issues
  • Alerts
    • E­mail Alerts
    • RSS Feeds
  • Podcasts
    • Diabetes Core Update
    • Special Podcast Series: Therapeutic Inertia
    • Special Podcast Series: Influenza Podcasts
    • Special Podcast Series: SGLT2 Inhibitors
    • Special Podcast Series: COVID-19
  • Submit
    • Submit a Manuscript
    • Journal Policies
    • Instructions for Authors
    • ADA Peer Review
Type 1 Diabetes at a Crossroads

Pathway to Artificial Pancreas Systems Revisited: Moving Downstream

  1. Aaron Kowalski⇑
  1. JDRF, New York, NY
  1. Corresponding author: Aaron Kowalski, akowalski{at}jdrf.org.
Diabetes Care 2015 Jun; 38(6): 1036-1043. https://doi.org/10.2337/dc15-0364
PreviousNext
  • Article
  • Figures & Tables
  • Info & Metrics
  • PDF
Loading

Abstract

Artificial pancreas (AP) systems, a long-sought quest to replicate mechanically islet physiology that is lost in diabetes, are reaching the clinic, and the potential of automating insulin delivery is about to be realized. Significant progress has been made, and the safety and feasibility of AP systems have been demonstrated in the clinical research center and more recently in outpatient “real-world” environments. An iterative road map to AP system development has guided AP research since 2009, but progress in the field indicates that it needs updating. While it is now clear that AP systems are technically feasible, it remains much less certain that they will be widely adopted by clinicians and patients. Ultimately, the true success of AP systems will be defined by successful integration into the diabetes health care system and by the ultimate metric: improved diabetes outcomes.

Introduction

An electromechanical approach to improve glycemic control and quality of life for people with diabetes—an artificial pancreas (AP) (or an automated insulin-delivery system or bionic pancreas)—has been a long-sought technological goal of diabetes researchers (1). However, a number of significant challenges needed to be overcome to deliver an AP system to people with diabetes. The past 10 years have seen many of these challenges addressed, and recent studies have demonstrated compelling safety and efficacy of the prototype systems (2). Technical feasibility is only a step toward declaring victory. Research and development efforts will continue to improve upon first-generation AP systems. But, it is clear that resources will need to be deployed to address clinical adoption challenges—including device usability and reimbursement.

Research and development efforts over the past 10 years have addressed a number of the critical issues facing AP development, and recent studies again signal a move to a new phase and a call for a new road map to AP systems. A number of groups have demonstrated proof of concept with a variety of algorithmic approaches and closed-loop strategies and the data are compelling. In a Bench to Clinic narrative, Cefalu and Tamborlane (3) dive much deeper than this Perspective intends into the “how” of AP systems. They note quite astutely that “it is not the journey, but the destination that matters” (3).

It may come as a surprise to many clinicians, but a small and growing group of lay, “do-it-yourself,” technically savvy people with diabetes or loved ones of people with diabetes has been using semiautomated closed-loop systems at home for well over 2 years with impressive results (4–6). These systems, similar to systems being studied in academic studies, combine off-the-shelf insulin pumps and continuous glucose monitors with control algorithms (computer software that interprets glucose information and drives the dosing of insulin) powered by cell phone devices. The results from academia and these anecdotal reports are harbingers of a technological revolution in diabetes and signal that AP system availability is no longer a matter of “if” but rather a matter of “when.”

The ultimate metric for success of AP systems will be improved outcomes for people with diabetes. The technical feasibility demonstrated to date raises a series of very important questions that this Perspective will attempt to answer, or at least provide fodder for debate. AP systems will provide an interesting case study in the importance of a field having line of sight beyond the research laboratory and through to all of the stages of a commercial development pathway from regulatory approval, to reimbursement, to clinical adoption. For AP systems to improve diabetes outcomes, they will need to be designed to be impactful across a diverse group of people with diabetes and will need to be accessible. AP system accessibility will be driven by the value perceived by two other crucial stakeholders—health care providers and payers. The pathway to the development of an AP has become much more complex than the road map that was created in 2009, and a new road map that addresses postresearch considerations needs to be drawn.

Key Question: What is an AP?

Answer: There Is No Singular AP—Technologies Will Evolve to Become More Automated

This may seem like an obvious question, but the literature has demonstrated significant inconsistency in this definition and this inconsistency has led to confusion. This Perspective will focus on the nearest-term AP systems. The core elements of these AP systems will be an insulin infusion pump, a continuous glucose monitor, a control algorithm, and rapid-acting insulin analogs (in some cases, there may be a handheld control device). Reports in the literature use a wide variety of terminology (artificial pancreas, bionic pancreas, closed loop, automated insulin delivery device, and treat-to-range system [7–11]) because there is no, nor will there ever be, a singular AP. Rather, these systems will evolve over time to increase in automation, increase in sophistication, and increase in their ability to normalize blood glucose levels. In the near term, these “AP systems” will reduce hypoglycemia (low-glucose and predictive low-glucose management systems) through the reduction or cessation of insulin delivery, will begin to automatically dose insulin to target ranges (hybrid closed-loop systems, hyperglycemia/hypoglycemia-minimizing systems, and semiautomated insulin delivery systems), and eventually will dose hormones in addition to insulin such as glucagon and/or amylin (bionic pancreas, dual-hormone AP, and multihormone AP).

In 2006, JDRF launched an initiative intended to accelerate progress toward AP systems (12). At that time, many questions existed regarding the technical feasibility and safety of automated insulin delivery. These questions continue (13). A road map was published that intended to describe how an evolutionary process of system development could lead to the commercialization of clinically meaningful systems that addressed unmet needs in the management of diabetes (Fig. 1) (14). This road map intended to address these questions and, importantly, create clearly defined “target product profiles” that could guide research funding and commercial development based upon the state of technology at the time. This road map intended to shift the focus from replication of islet function with a machine to iterative improvements that addressed unmet clinical needs through increasing automation of insulin delivery.

Figure 1
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 1

2009 AP road map. A target-product profile-based approach to envision iterative steps of increasing automation of insulin delivery initially toward a more physiological multihormone delivery eventually.

It should be noted that this road map includes both systems that reduce/stop insulin delivery due to hypoglycemia or impending hypoglycemia (Fig. 1, boxes 1 and 2) as well as systems that automate the delivery of insulin (Fig. 1, boxes 3–6). All of these systems were described as AP systems, the criteria being the automation of the control of insulin delivery from an insulin pump. That said, there is certainly a significant step from reducing insulin delivery to increasing insulin delivery (Fig. 1, box 3), and many consider the first AP systems to begin at this point. This Perspective will discuss hypoglycemia-minimizing systems, but will use the term AP systems and synonyms to describe and discuss future systems that dose insulin and other hormones automatically.

Key Questions: Do We Need AP Systems? Is There an Unmet Need? Are Diabetes Outcomes Suboptimal Because Tools Are Lacking or Because of Lack of Compliance With Today’s Therapies?

Answers: Yes to All

The unmet medical need in diabetes is striking. Despite extensive knowledge of the damage of hyperglycemia and the passage of 23 years since the Diabetes Control and Complications Trial (DCCT) (15), glycemic control levels in the U.S. remain suboptimal. Current clinical evidence, including data from the T1D Exchange registry, paints a picture that is full of opportunity for significant improvement across all diabetes outcomes measured. The data on important diabetes outcomes paints a sobering picture.

A1C Levels

In the U.S., A1C levels remain elevated with <20% of children and young adults and <40% of adults >25 years of age meeting A1C targets (16).

Hypoglycemia

Hypoglycemia has been defined (17) and measured in a number of different ways. However, the data remain consistent that hypoglycemia is frequent by all measures and that it remains the limiting barrier to tight glycemic control (18–20).

Diabetic Ketoacidosis

Diabetic ketoacidosis is a life-threatening and costly acute complication. The rates remain elevated in the U.S. and globally (19,21).

Time in Range

Time in range is an intuitive metric for glycemic control that captures hyper-, hypo-, and normoglycemia in one simple view. This metric has only been possible to capture since the launch of continuous glucose monitoring (CGM) devices. A challenge in measuring time in target is the definition of the target range or the “normal” range. The definition of the range has varied in the literature (i.e., 70–105, 70–120, 70–180 mg/dL) (22–24). Whatever the target range that is used, people with diabetes are far from achieving normoglycemia.

Patient-Reported Outcomes

The impact of diabetes remains significant on patients beyond suboptimal glycemic control. People with diabetes still suffer from significantly elevated levels of anxiety, depression, and other psychosocial issues due to a number of reasons, including the high burden that diabetes management places on the patient (25,26).

The obvious question is why? Why are glycemic control goals not being achieved? With crystal-clear evidence of the morbidity associated with hyperglycemia and hypoglycemia, why are only a fraction of people with diabetes achieving recommended glycemic and metabolic goals? There are many reasons that vary from individual to individual, but it is clear that the tools today do not easily allow for the normalization of glycemia for patients lacking β-cell function. Self-monitoring of blood glucose levels (27), continuous subcutaneous insulin infusion (28), CGM (18), and now low-glucose suspend (LGS) pumps (29) have all been demonstrated to significantly improve glycemic control either by reducing A1C or hypoglycemia levels. However, wide glucose excursions above and below the target range persist in almost all patients and attempts to achieve tighter and tighter glycemic control take more and more effort with diminishing returns. It is striking that children in the JDRF CGM trial, who were intensively managed, met with clinic staff regularly, wore CGM devices, mostly wore insulin infusion pumps, and finger-stick tested seven times a day, spent greater than 10 h a day with sugar levels above 180 mg/dL; and the adults spent more than 6 h a day with sugar levels above 180 mg/dL (18). It would be very difficult to argue that this was a noncompliant patient population. Clearly today’s tools have helped improve glucose control and in some cases reduce some of the burden of diabetes management. However, these data also clearly support that compliance is not the only barrier to optimal glycemic control.

Key Questions: Are AP Systems Technically Feasible Today? Can an AP System Replicate the Function of the Islet?

Answers: Yes and No

There remains a debate in the literature and at diabetes conferences regarding the technical feasibility of AP systems given the state of the technology today. There are strong believers (14) and others who have questioned if a machine can ever replicate the sophistication of the islet (13). Unfortunately, much of this debate stems from a misframing of the argument. For example, those who believe that it will not be possible for today’s technologies to replicate the complex regulation of islet hormone secretions are probably correct. It is highly unlikely that we will normalize blood glucose levels though subcutaneous replacement of insulin alone (or even with insulin and glucagon). However a significant reduction of glycemic burden, both hyperglycemic and hypoglycemic, is possible with today’s technology, and as technology improves and insulin delivery and/or kinetics become more physiological, the bulk of glycemic excursions may be avoided. Therefore, we should not be comparing AP systems to physiological islet function; rather, we should be addressing unmet needs in current diabetes management that can be solved with technical solutions. Expectation setting will be very important as AP systems become commercialized and reach clinics. First-generation AP systems will not restore euglycemia and will not be fully automated, but they will significantly improve glycemia and reduce diabetes management burden in many patients.

AP systems are technically feasible today. Table 1 shows the six-step road map and references of representative studies demonstrating safety and efficacy. It is clear that AP systems outperform today’s standard of care significantly when benchmarked across a variety of diabetes outcome metrics. Larger studies are needed to gather A1C changes versus a randomized comparator, but the data to date is compelling and convincing. AP systems work.

View this table:
  • View inline
  • View popup
Table 1

AP road map in 2015: proof of concept of five of six steps of iteratively more sophisticated AP systems has been demonstrated in outpatient trials

Key Question: Must AP Systems Use Glucagon?

Answer: Glucagon Is Not Essential but May Provide Additional Benefits

A widely debated question in the field of AP research is whether the use of glucagon is necessary to build a safe system. Again, the data are convincing that insulin-alone–based systems will improve glycemic control, reduce hyperglycemia and/or hypoglycemia risk, and reduce some aspects of diabetes management burden (Table 1). The short answer to this question is therefore no—glucagon will not be essential for AP systems to reach the market. That said, results from insulin/glucagon studies have been outstanding and have generated enthusiasm in the field (9,30,31) and in the popular press (32). Conceptually, an insulin/glucagon approach is appealing. In the native/nondiabetic islet, the cross talk between α- and β-cells and the liver contributes to the intricate balance between gluconeogenesis and glycogenolysis and the maintenance of exquisitely tight glucose regulation within a very narrow range (33). A logical conclusion might be that AP systems would also benefit from such a bihormonal approach. However, more research will be needed to address significant questions regarding the consequences of glucagon infusion set failure and failure of the liver to respond to glucagon. Bakhtiani et al. (10) found that glucagon failed to prevent hypoglycemia and that these failures occurred more frequently when glucagon is delivered while glucose is falling rapidly, at a lower glucose threshold, and when there are high levels of insulin on board. El Youssef et al. (34) demonstrated that glucagon failed to prevent hypoglycemia ∼20% of the time in their initial studies. Pragmatic issues also remain, such as the need for a soluble pumpable glucagon and a dual-chambered pump and cost (35). In the coming years, it will be important to define the incremental value of glucagon and to define strategies to avoid glucagon “failure.” The Helmsley Charitable Trust, National Institute of Diabetes and Digestive and Kidney Diseases, JDRF, and the industry have invested significant resources to accelerate solutions to these challenges.

Hormones Beyond Glucagon

Another multihormone approach that has received less attention is the combination of insulin and amylin. Conceptually, this approach is appealing. The loss of β-cell function leads to the obvious loss of insulin production but also amylin production as well (36). Amylin plays an important role physiologically by suppressing glucagon production, contributing to regulation of gastric emptying, and impacting satiety. Amylin replacement through multiple daily injections of the amylin analog pramlintide has achieved limited uptake in the clinic (16). Pilot studies of multihormone AP systems using insulin and pramlintide have demonstrated impressive results (37). The same pragmatic issues exist for pramlintide as for glucagon, and this remains an area of continued investigation.

Key Questions: Where Do We Go From Here? What AP Systems Will Reach the Clinic and When?

Answer: AP Systems Must Demonstrate Value to Patients, Providers, and Payers to Be Successful; Value Will Be Defined by More Than A1C Changes

AP systems must reach people with diabetes and improve outcomes. To do so, they must receive U.S. Food and Drug Administration (FDA)/regulatory body approval, be commercialized, be reimbursable, and be adopted by providers and patients. In 2012, the FDA issued final guidance that provided a pathway for manufacturers to commercialize AP systems (38), opening the door for commercial development AP systems to reach the market. A major challenge to the translation of novel diabetes therapies into practice has been that the success of the therapy was judged with very narrow metrics that were heavily weighted to A1C. On the other hand, patients, clinicians, insurance companies, and government agencies weigh the benefits of new therapies by many other factors. Clearer descriptions of these factors may help inform the evolution and ultimate success of AP systems and future diabetes interventions.

Diabetes Scorecard

Ultimately, success of a novel technology should be measured by the improvement in outcomes across the population with type 1 diabetes (T1D), which can only be achieved if clinically effective therapies are covered by payers, prescribed by physicians, and used by people with T1D who could benefit. Therapies well positioned for success will improve glycemic outcomes and reduce disease management burden at a cost consistent with the benefit provided by the therapy. In other words, therapies must provide a good value for people with diabetes but also for the health care professionals treating their diabetes and for the payers covering treatment, each of which has somewhat different perspectives on what constitutes value.

JDRF is developing a “T1D Scorecard,” a tool (or tools) that will provide a framework for evaluating the value of new diabetes technologies/therapies that is framed by the key attributes that are important to each stakeholder (Fig. 2). While Fig. 2 is not an exhaustive list, it highlights attributes that each stakeholder may weigh when evaluating new technologies. JDRF looks forward to working with other stakeholders to define a set of clinical outcomes by which to judge T1D therapies that is broader than A1C and to identify measures of disease management burden.

Figure 2
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 2

For new technologies to succeed, they must demonstrate value to key stakeholders. An example/nonexhaustive list of areas of importance is shown.

Key Question: Where Will the AP Field Head in the Next 10 Years?

Answer: Automated Insulin Delivery Systems Have a Clear Path to the Market and the Focus Will Likely Shift to Reduction in Burden and Cost, and Multihormone Systems Need to Overcome Pragmatic Challenges to Reach the Market and Then Demonstrate Improved Glycemic Benefit and Burden Reduction to Drive Adoption (Compared With Automated Insulin-Alone Systems)

In light of the progress that has been made over the past 6 years, the six-step pathway for iteratively more advanced AP systems that was proposed in 2009 needs updating. This iterative pathway aimed to address technical limitations in glucose sensing and insulin delivery while positively impacting important diabetes outcomes. The data support that today’s technologies are ready to automate some degree of insulin delivery. In fact, for a small population of people, they already are. Boxes 1 and 2 in Fig. 1 are technically complete and the data support that they are safe and efficacious. Therefore, in 2015 the road map looks different and the obstacles have changed. Certainly, there are further technical advances that will allow for more sophisticated systems. But where should the focus be for that evolution?

Bifurcation in Pathway

Figure 3 proposes a new AP pathway—one that is bifurcated. Today, the pathway has evolved. Encouragingly, two of the six steps have been technically completed. In 2010, Medtronic released the first threshold-suspend system in Europe and in 2014 in the U.S. Such a system was a logical and important first step. Prior to its release and to date for all other insulin infusion pumps, insulin infusion continued even in the face of profound hypoglycemia and even while CGM alarms signal such lows. Cessation of insulin delivery during this time, while simple, held the potential to reduce hypoglycemic exposure and potentially profound hypoglycemia events. Studies of this system have validated this hypothesis (29,39). A more powerful approach to hypoglycemia reduction will be predictive suspension of insulin delivery with impending hypoglycemia. This approach improves glycemic outcomes (reduced hypoglycemia exposure, potentially reduced mean blood glucose vs. threshold-suspend system due to autoresumption of basal insulin delivery, and the interesting potential restoration of some counterregulation and hypoglycemia awareness) and provides reduction of burden (fewer alarms, reduced fear of hypoglycemia). It is also expected to be comparable in cost to threshold-suspend systems.

Figure 3
  • Download figure
  • Open in new tab
  • Download powerpoint
Figure 3

Revised AP road map. AP system development can be condensed from six steps to three and has bifurcated into automated insulin delivery approaches utilizing solely insulin (AID) and multihormone approaches (MH), which may utilize insulin and glucagon, insulin and amylin, or insulin and other glucose-modulating agents.

A Split

Whereas boxes 3–5 in Fig. 1 focus on reduction of hyperglycemia through an iterative increase in automation and box 6 focuses on multihormone approaches, today a more logical presentation of potential pathways is a split into two parallel avenues. One avenue will encompass automated insulin-alone delivery (AID) systems and another will be systems that incorporate another hormone or hormones.

AID

Of these two pathways, AID systems are likely to reach the clinic first. Many studies have demonstrated safety and efficacy and the technical barriers are low. The first systems to reach the clinic will likely be “hybrid” treat-to-range or treat-to-target systems that require mealtime bolusing and then provide automated functionality that drives glucose levels back to a near-normal level (100–140 mg/dL in studies to date) during the rest of the day and night. The control algorithms that provide the automation of insulin delivery also provide the framework from moving seamlessly from systems that solely reduce/stop insulin delivery to those that add automated increases in insulin delivery as well (40). The focus of future AID system development will be across the three categories of the Diabetes Scorecard.

Glycemic Outcomes.

The main barrier to further improvements in glycemic outcomes (beyond a hypoglycemia hyperglycemic minimizer or hybrid AP systems) and to further automation of the system is the delay in the absorption and action of subcutaneously injected insulin. Other technological improvements, such as self-learning algorithms, integration of accelerometers, and better bolus calculators, may help incrementally improve glycemic outcomes and minimize user actions, but a more rapid insulin profile will be required to truly approach euglycemia and eliminate user prandial dosing in an AID system.

Disease Management Burden.

The more likely area of significant return on investment will be in the development of systems that reduce the burdens and barriers to CGM and insulin pump adoption. These will likely include calibration-free CGM, smaller CGM transmitters, smaller “tethered” and “patch” pumps, cell phone integration, and cloud-based data analytics.

Cost/Value.

The cost of AID systems should reflect the technology’s ability to impact glycemic outcomes and disease management burden. High-value systems will be appealing to all three key diabetes constituencies. Dual-hormone systems will likely require more time to reach the clinic (vs. AID systems) as practical and research questions are addressed. When compared with AID systems, a novel specialized pump will be necessary, and a specialized dual-lumen or modified infusion set as well as the additional hormone will be needed. These additional costs will need to be quantified and considered against the potential for improved glycemic control with a dual-hormone approach. To date, there exists very limited data comparing dual-hormone to an insulin-alone AP system (31). Further studies comparing best-in-class insulin-alone approaches to best-in-class multihormone systems should be a top priority to clearly define the pros and cons of each approach. Reduction of hypoglycemia, particularly severe hypoglycemia, represents a potentially significant benefit to glucagon/insulin AP approaches. While potentially more expensive, they may demonstrate additional value to the people with diabetes, health care professionals, and payers, and data supporting this argument will be very important.

Summary

For the past half century, AP technologies have been the “holy grail” of diabetes treatment. However, the sophisticated glucose regulation provided by the islet and the related metabolic physiology are difficult to replicate with a machine. The evolution of portable, small, easy-to-use, and efficacious insulin infusion pumps, continuous glucose monitors, and control algorithms over the past decade has allowed for proof-of-concept approaches—AP systems—that, while not perfect replications of islet biology, may provide significant value. The first automated insulin delivery systems that automatically reduce hypoglycemia exposure are already commercialized and are being used in clinical practice. AP systems that begin the dosing of some insulin automatically are expected in the 2017 time frame in the U.S., as reported from the J.P. Morgan Healthcare Conference in January 2015.

This progress has raised new questions and areas of focus. Success of AP systems will be defined by better diabetes outcomes. Better diabetes outcomes will include more than improved A1C (41). Broader understanding of the important glycemic outcomes in particular patient segments is needed. Furthermore, technologies will only be adopted and better outcomes achieved if they provide good value—improved glycemic outcomes and reduced burden at a cost consistent with the benefit provided by the technology. Ideally, next-generation diabetes therapeutics, AP systems, and beyond will improve glycemic outcomes, reduce burden, and provide value beyond today’s therapies and approaches. Improvement on any of these three scores for all of the three key stakeholders—patients, health care professionals, and payers—will portend well for novel technologies. Therapies that do not provide good value to all three stakeholders will face challenges to being widely adopted.

Article Information

Acknowledgments. The author thanks his colleagues at JDRF, particularly Dr. Richard Insel, Cynthia Rice, Jessica Roth, Campbell Hutton, and Dr. Vincent Crabtree, for their thoughtful suggestions. He also thanks Dr. Roy Beck, John Lum, the JDRF Artificial Pancreas Consortium, and David Panzirer of the Helmsley Trust for countless hours studying, discussing, and debating the future of AP systems and thanks the diabetes device manufacturers who have supported AP research over the past 10 years and are working to deliver commercial AP systems to people with diabetes.

Duality of Interest. No potential conflicts of interest relevant to this article were reported.

Footnotes

  • See accompanying articles, pp. 968, 971, 979, 989, 997, 1008, 1016, and 1030.

  • Received February 18, 2015.
  • Accepted March 27, 2015.
  • © 2015 by the American Diabetes Association. Readers may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered.

References

  1. ↵
    1. Schatz H,
    2. Pfeiffer EF
    . The endocrine pancreas. From the isolated islet to the “artificial pancreas” (author’s transl). MMW Munch Med Wochenschr 1976;118:485–492 [in German]pmid:818514
    OpenUrlPubMed
  2. ↵
    1. Skyler JS
    . T1DM in 2014: progress towards a bionic pancreas. Nat Rev Endocrinol 2015;11:75–76pmid:25534194
    OpenUrlPubMed
  3. ↵
    1. Cefalu WT,
    2. Tamborlane WV
    . The artificial pancreas: are we there yet? Diabetes Care 2014;37:1182–1183pmid:24757224
    OpenUrlFREE Full Text
  4. ↵
    Hurley D. Diabetes patients are hacking their way toward a bionic pancreas [article online], 2014. Available from http://www.wired.com/2014/12/diabetes-patients-hacking-together-diy-bionic-pancreases/. Accessed 24 December 2014
  5. Kimball S. Meet the bigfoot family and their homemade closed loop system [Internet], 2015. Available from http://www.healthline.com/diabetesmine/bigfoot-family-their-diabetes-and-homemade-closed-loop-system#1. Accessed 4 March 2015
  6. ↵
    @danamlewis. #DIYPS [Internet]. Available from diyps.org. Accessed 7 February 2015
  7. ↵
    1. Peyser T,
    2. Dassau E,
    3. Breton M,
    4. Skyler JS
    . The artificial pancreas: current status and future prospects in the management of diabetes. Ann N Y Acad Sci 2014;1311:102–123pmid:24725149
    OpenUrlCrossRefPubMed
    1. Lee JJ,
    2. Dassau E,
    3. Zisser H,
    4. Doyle FJ 3rd
    . Design and in silico evaluation of an intraperitoneal-subcutaneous (IP-SC) artificial pancreas. Comput Chem Eng 2014;70:180–188pmid:25267863
    OpenUrlCrossRefPubMed
  8. ↵
    1. Russell SJ,
    2. El-Khatib FH,
    3. Sinha M, et al
    . Outpatient glycemic control with a bionic pancreas in type 1 diabetes. N Engl J Med 2014;371:313–325pmid:24931572
    OpenUrlCrossRefPubMed
  9. ↵
    1. Bakhtiani PA,
    2. El Youssef J,
    3. Duell AK, et al
    . Factors affecting the success of glucagon delivered during an automated closed-loop system in type 1 diabetes. J Diabetes Complications 2015;29:93–98pmid:25264232
    OpenUrlCrossRefPubMed
  10. ↵
    1. Brown SA,
    2. Kovatchev BP,
    3. Breton MD, et al
    . Multinight “bedside” closed-loop control for patients with type 1 diabetes. Diabetes Technol Ther 2015;17:203–209pmid:25594434
    OpenUrlCrossRefPubMed
  11. ↵
    1. Kowalski A,
    2. Lum JW
    . Juvenile diabetes research foundation artificial pancreas consortium update. J Diabetes Sci Tech 2009;3:1224–1226pmid:20144441
    OpenUrlFREE Full Text
  12. ↵
    1. Winikoff J,
    2. Drexler A
    . Who needs an artificial pancreas? J Diabetes 2013;5:254–257pmid:23601378
    OpenUrlCrossRefPubMed
  13. ↵
    1. Kowalski AJ
    . Can we really close the loop and how soon? Accelerating the availability of an artificial pancreas: a roadmap to better diabetes outcomes. Diabetes Technol Ther 2009;11(Suppl. 1):S113–S119pmid:19621478
    OpenUrlCrossRefPubMedWeb of Science
  14. ↵
    The Diabetes Control and Complications Trial Research Group. The effect of intensive treatment of diabetes on the development and progression of long-term complications ininsulin-dependent diabetes mellitus. N Engl J Med 1993;329:977–986pmid:8366922
    OpenUrlCrossRefPubMedWeb of Science
  15. ↵
    1. Beck RW,
    2. Tamborlane WV,
    3. Bergenstal RM,
    4. Miller KM,
    5. DuBose SN,
    6. Hall CA; T1D Exchange Clinic Network
    . The T1D Exchange clinic registry. J Clin Endocrinol Metab 2012;97:4383–4389pmid:22996145
    OpenUrlCrossRefPubMedWeb of Science
  16. ↵
    1. Seaquist ER,
    2. Anderson J,
    3. Childs B, et al
    . Hypoglycemia and diabetes: a report of a workgroup of the American Diabetes Association and the Endocrine Society. Diabetes Care 2013;36:1384–1395pmid:23589542
    OpenUrlAbstract/FREE Full Text
  17. ↵
    1. Tamborlane WV,
    2. Beck RW,
    3. Bode BW, et al, .; Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group
    . Continuous glucose monitoring and intensive treatment of type 1 diabetes. N Engl J Med 2008;359:1464–1476pmid:18779236
    OpenUrlCrossRefPubMedWeb of Science
  18. ↵
    1. Cengiz E,
    2. Xing D,
    3. Wong JC, et al, .; T1D Exchange Clinic Network
    . Severe hypoglycemia and diabetic ketoacidosis among youth with type 1 diabetes in the T1D Exchange clinic registry. Pediatr Diabetes 2013;14:447–454pmid:23469984
    OpenUrlCrossRefPubMed
  19. ↵
    1. Maahs DM,
    2. Calhoun P,
    3. Buckingham BA, et al, .; In Home Closed Loop Study Group
    . A randomized trial of a home system to reduce nocturnal hypoglycemia in type 1 diabetes. Diabetes Care 2014;37:1885–1891pmid:24804697
    OpenUrlAbstract/FREE Full Text
  20. ↵
    1. Livingstone SJ,
    2. Levin D,
    3. Looker HC, et al, .; Scottish Diabetes Research Network epidemiology group, ; Scottish Renal Registry
    . Estimated life expectancy in a Scottish cohort with type 1 diabetes, 2008-2010. JAMA 2015;313:37–44pmid:25562264
    OpenUrlCrossRefPubMed
  21. ↵
    1. Bode BW,
    2. Schwartz S,
    3. Stubbs HA,
    4. Block JE
    . Glycemic characteristics in continuously monitored patients with type 1 and type 2 diabetes: normative values. Diabetes Care 2005;28:2361–2366pmid:16186263
    OpenUrlAbstract/FREE Full Text
    1. Fox LA,
    2. Beck RW,
    3. Xing D; Juvenile Diabetes Research Foundation Continuous Glucose Monitoring Study Group
    . Variation of interstitial glucose measurements assessed by continuous glucose monitors in healthy, nondiabetic individuals. Diabetes Care 2010;33:1297–1299pmid:20215454
    OpenUrlAbstract/FREE Full Text
  22. ↵
    1. Leelarathna L,
    2. Dellweg S,
    3. Mader JK, et al, .; AP@home Consortium
    . Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study. Diabetes Care 2014;37:1931–1937pmid:24963110
    OpenUrlAbstract/FREE Full Text
  23. ↵
    1. Northam EA,
    2. Lin A,
    3. Finch S,
    4. Werther GA,
    5. Cameron FJ
    . Psychosocial well-being and functional outcomes in youth with type 1 diabetes 12 years after disease onset. Diabetes Care 2010;33:1430–1437pmid:20357379
    OpenUrlAbstract/FREE Full Text
  24. ↵
    1. Ducat L,
    2. Rubenstein A,
    3. Philipson LH,
    4. Anderson BJ
    . A review of the mental health issues of diabetes conference. Diabetes Care 2015;38:333–338pmid:25614689
    OpenUrlAbstract/FREE Full Text
  25. ↵
    1. Strowig SM,
    2. Raskin P
    . Improved glycemic control in intensively treated type 1 diabetic patients using blood glucose meters with storage capability and computer-assisted analyses. Diabetes Care 1998;21:1694–1698pmid:9773733
    OpenUrlAbstract/FREE Full Text
  26. ↵
    1. John P
    . Insulin pumps. Diabetes Technol Ther 2014;16(Suppl. 1):S17–S22
    OpenUrlCrossRefPubMed
  27. ↵
    1. Ly TT,
    2. Nicholas JA,
    3. Retterath A,
    4. Lim EM,
    5. Davis EA,
    6. Jones TW
    . Effect of sensor-augmented insulin pump therapy and automated insulin suspension vs standard insulin pump therapy on hypoglycemia in patients with type 1 diabetes: a randomized clinical trial. JAMA 2013;310:1240–1247pmid:24065010
    OpenUrlCrossRefPubMedWeb of Science
  28. ↵
    1. Jacobs PG,
    2. El Youssef J,
    3. Castle J, et al
    . Automated control of an adaptive bihormonal, dual-sensor artificial pancreas and evaluation during inpatient studies. IEEE Trans Biomed Eng 2014;61:2569–2581pmid:24835122
    OpenUrlCrossRefPubMed
  29. ↵
    1. Haidar A,
    2. Legault L,
    3. Messier V,
    4. Mitre TM,
    5. Leroux C,
    6. Rabasa-Lhoret R
    . Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial. Lancet Diabetes Endocrinol 2015;3:17–26pmid:25434967
    OpenUrlCrossRefPubMed
  30. ↵
    Alexandra S. 29 January 2015. The next best thing to a cure for diabetes. Time Magazine: 44–46
  31. ↵
    1. Ramnanan CJ,
    2. Edgerton DS,
    3. Kraft G,
    4. Cherrington AD
    . Physiologic action of glucagon on liver glucose metabolism. Diabetes Obes Metab 2011;13(Suppl. 1):118–125pmid:21824265
    OpenUrlPubMed
  32. ↵
    1. El Youssef J,
    2. Castle JR,
    3. Branigan DL, et al
    . A controlled study of the effectiveness of an adaptive closed-loop algorithm to minimize corticosteroid-induced stress hyperglycemia in type 1 diabetes. J Diabetes Sci Tech 2011;5:1312–1326pmid:22226248
    OpenUrlAbstract/FREE Full Text
  33. ↵
    1. Rylander D Jr
    . Glucagon in the artificial pancreas: supply and marketing challenges. J Diabetes Sci Tech 2015;9:52–55pmid:25139825
    OpenUrlAbstract/FREE Full Text
  34. ↵
    1. Edelman S,
    2. Maier H,
    3. Wilhelm K
    . Pramlintide in the treatment of diabetes mellitus. BioDrugs 2008;22:375–386pmid:18998755
    OpenUrlCrossRefPubMedWeb of Science
  35. ↵
    1. Weinzimer SA,
    2. Sherr JL,
    3. Cengiz E, et al
    . Effect of pramlintide on prandial glycemic excursions during closed-loop control in adolescents and young adults with type 1 diabetes. Diabetes Care 2012;35:1994–1999pmid:22815298
    OpenUrlAbstract/FREE Full Text
  36. ↵
    U.S. Food and Drug Administration. Guidance for industry and food and drug administration staff: the content of investigational device exemption (IDE) and premarket approval (PMA) applications for artificial pancreas device systems [Internet], 2012. Available from http://www.fda.gov/downloads/MedicalDevices/DeviceRegulationandGuidance/GuidanceDocuments/UCM259305.pdf. Accessed 9 November 2012
  37. ↵
    1. Agrawal P,
    2. Zhong A,
    3. Welsh JB,
    4. Shah R,
    5. Kaufman FR
    . Retrospective analysis of the real-world use of the threshold suspend feature of sensor-augmented insulin pumps. Diabetes Technol Ther. 22 January 2015 [Epub ahead of print]
  38. ↵
    1. Breton M,
    2. Farret A,
    3. Bruttomesso D, et al, .; International Artificial Pancreas Study Group
    . Fully integrated artificial pancreas in type 1 diabetes: modular closed-loop glucose control maintains near normoglycemia. Diabetes 2012;61:2230–2237pmid:22688340
    OpenUrlAbstract/FREE Full Text
  39. ↵
    1. Kowalski AJ,
    2. Dutta S
    . It's time to move from the A1c to better metrics for diabetes control. Diabetes Technol Ther 2013;15:194–196
    OpenUrlCrossRefPubMed
    1. Phillip M,
    2. Battelino T,
    3. Atlas E, et al
    . Nocturnal glucose control with an artificial pancreas at a diabetes camp. N Engl J Med 2013;368:824–833pmid:23445093
    OpenUrlCrossRefPubMedWeb of Science
    1. Bergenstal RM,
    2. Klonoff DC,
    3. Garg SK, et al, .; ASPIRE In-Home Study Group
    . Threshold-based insulin-pump interruption for reduction of hypoglycemia. N Engl J Med 2013;369:224–232pmid:23789889
    OpenUrlCrossRefPubMedWeb of Science
    1. Buckingham BA,
    2. Cameron F,
    3. Calhoun P, et al
    . Outpatient safety assessment of an in-home predictive low-glucose suspend system with type 1 diabetes subjects at elevated risk of nocturnal hypoglycemia. Diabetes Technol Ther 2013;15:622–627pmid:23883408
    OpenUrlCrossRefPubMed
    1. Kovatchev BP,
    2. Renard E,
    3. Cobelli C, et al
    . Safety of outpatient closed-loop control: first randomized crossover trials of a wearable artificial pancreas. Diabetes Care 2014;37:1789–1796pmid:24929429
    OpenUrlAbstract/FREE Full Text
    1. Weinzimer SA,
    2. Steil GM,
    3. Swan KL,
    4. Dziura J,
    5. Kurtz N,
    6. Tamborlane WV
    . Fully automated closed-loop insulin delivery versus semiautomated hybrid control in pediatric patients with type 1 diabetes using an artificial pancreas. Diabetes Care 2008;31:934–939pmid:18252903
    OpenUrlAbstract/FREE Full Text
PreviousNext
Back to top
Diabetes Care: 38 (6)

In this Issue

June 2015, 38(6)
  • Table of Contents
  • Table of Contents (PDF)
  • About the Cover
  • Index by Author
  • Masthead (PDF)
Sign up to receive current issue alerts
View Selected Citations (0)
Print
Download PDF
Article Alerts
Sign In to Email Alerts with your Email Address
Email Article

Thank you for your interest in spreading the word about Diabetes Care.

NOTE: We only request your email address so that the person you are recommending the page to knows that you wanted them to see it, and that it is not junk mail. We do not capture any email address.

Enter multiple addresses on separate lines or separate them with commas.
Pathway to Artificial Pancreas Systems Revisited: Moving Downstream
(Your Name) has forwarded a page to you from Diabetes Care
(Your Name) thought you would like to see this page from the Diabetes Care web site.
CAPTCHA
This question is for testing whether or not you are a human visitor and to prevent automated spam submissions.
Citation Tools
Pathway to Artificial Pancreas Systems Revisited: Moving Downstream
Aaron Kowalski
Diabetes Care Jun 2015, 38 (6) 1036-1043; DOI: 10.2337/dc15-0364

Citation Manager Formats

  • BibTeX
  • Bookends
  • EasyBib
  • EndNote (tagged)
  • EndNote 8 (xml)
  • Medlars
  • Mendeley
  • Papers
  • RefWorks Tagged
  • Ref Manager
  • RIS
  • Zotero
Add to Selected Citations
Share

Pathway to Artificial Pancreas Systems Revisited: Moving Downstream
Aaron Kowalski
Diabetes Care Jun 2015, 38 (6) 1036-1043; DOI: 10.2337/dc15-0364
del.icio.us logo Digg logo Reddit logo Twitter logo CiteULike logo Facebook logo Google logo Mendeley logo
  • Tweet Widget
  • Facebook Like
  • Google Plus One

Jump to section

  • Article
    • Abstract
    • Introduction
    • Key Question: What is an AP?
    • Key Questions: Do We Need AP Systems? Is There an Unmet Need? Are Diabetes Outcomes Suboptimal Because Tools Are Lacking or Because of Lack of Compliance With Today’s Therapies?
    • Key Questions: Are AP Systems Technically Feasible Today? Can an AP System Replicate the Function of the Islet?
    • Key Question: Must AP Systems Use Glucagon?
    • Key Questions: Where Do We Go From Here? What AP Systems Will Reach the Clinic and When?
    • Key Question: Where Will the AP Field Head in the Next 10 Years?
    • Summary
    • Article Information
    • Footnotes
    • References
  • Figures & Tables
  • Info & Metrics
  • PDF

Related Articles

Cited By...

More in this TOC Section

  • Current State of Type 1 Diabetes Treatment in the U.S.: Updated Data From the T1D Exchange Clinic Registry
  • Current Concepts on the Pathogenesis of Type 1 Diabetes—Considerations for Attempts to Prevent and Reverse the Disease
  • Predicting Type 1 Diabetes Using Biomarkers
Show more Type 1 Diabetes at a Crossroads

Similar Articles

Navigate

  • Current Issue
  • Standards of Care Guidelines
  • Online Ahead of Print
  • Archives
  • Submit
  • Subscribe
  • Email Alerts
  • RSS Feeds

More Information

  • About the Journal
  • Instructions for Authors
  • Journal Policies
  • Reprints and Permissions
  • Advertising
  • Privacy Policy: ADA Journals
  • Copyright Notice/Public Access Policy
  • Contact Us

Other ADA Resources

  • Diabetes
  • Clinical Diabetes
  • Diabetes Spectrum
  • Scientific Sessions Abstracts
  • Standards of Medical Care in Diabetes
  • BMJ Open - Diabetes Research & Care
  • Professional Books
  • Diabetes Forecast

 

  • DiabetesJournals.org
  • Diabetes Core Update
  • ADA's DiabetesPro
  • ADA Member Directory
  • Diabetes.org

© 2021 by the American Diabetes Association. Diabetes Care Print ISSN: 0149-5992, Online ISSN: 1935-5548.